Download Print this page

Panasonic AW-RP50E Operating Instructions Manual page 93

Remote camera controller

Advertisement

Available languages

Available languages

Connections
2
On the [SYSTEM] menu, select [AUTO SET
IP], and display [AUTO SETUP]. Then select
RENEW, and press the F2 dial.
1 . A U T O S ET U P
Both the number of devices (all remote cameras and the
switcher) currently being managed by the unit and the
number of new devices detected are displayed on the
LCD panel.
C: 3 / 3
S : 1 / 1
Y E S
C: 3 / 3
Number of devices currently managed by the
unit + Number of new devices detected
Number of new devices detected
 Memo 
  If the number of new devices detected exceeds
the number of devices that can be registered
(100 remote cameras and 1 switcher), [C/S OVER!]
will be displayed at the bottom of the LCD panel.
Automatic IP address setting can be performed even
in this state, but IP addresses will be set only for the
number of devices that can be registered.
C: 20/100 S:1/1
C/ S OVER!
  The number displayed for "Number of new devices
detected" may be lower than the actual number of
devices to be set, due to a cause such as the remote
cameras or switches not being powered on. In this
case, eliminate the cause of the problem, select
"RETRY", and then press the F2 dial to retry the
operation.
The number of units to be added can be updated.
C : 2 0 / 2 0 S : 1 /1
R E NE W
C: Remote camera, S: Switcher
YES
R ET R Y
3
Turn the F2 dial, select "Yes," and then press
the F2 dial.
This starts the "Auto IP setting" process.
When "Auto IP setting" has been initiated, the progress
is shown by the number of displayed dots which are
reduced one by one.
SE T UP IP
When all the operations have been completed
successfully, "COMPLETE!" is displayed.
SE T UP IP
The remote cameras and the switcher are automatically
rebooted, and they restart with the new IP addresses
which were set.
The remote cameras can now be operated from the unit.
The function for linking the switcher with the unit
becomes available for use at this point.
 Memo 
If the IP addresses were not set successfully,
"SET UP ERR!" is displayed.
S ET UP IP
The cause of the problem is likely a network
malfunction.
Check the connection status of the hub and LAN cables,
and then retry the "Auto IP setting" operation.
24 (F)
CO MPL ET E!
S ET UP ER R!

Advertisement

loading