4. Picture monitor (PM) displays
p CAM Mode: Camera output signal format
The format for signals output from the camera is
displayed.
Display range: 59.94i, 50i
p CCU Mode: Formats of signals output from CCU
The selection status of the formats of the signals output
from the unit are displayed here.
Display range: 1080/59.94i (60i), 1080/50i (50i)
p Incom System ENG:
Engineering intercom system status
The status of the engineering intercom system is
displayed here.
Display range: RTS, 2W, 4W
p Incom System PROD:
Producer intercom system status
The status of the producer intercom system is displayed
here.
Display range: RTS, 2W, 4W
p Hours CAM: Camera's cumulative operation time
The camera's cumulative operation time (in hours) is
displayed here.
p Hours CCU: CCU's cumulative operation time
The unit's cumulative operation time (in hours) is
displayed here.
Status displays (page 5 of 5)
On the status display (page 4 of 5) screen, press the
character switch on the operation panel of the ROP or MSU
to display the fifth page of the status displays.
5/5
CABLE OPEN
CABLE SHORT
FAN ALARM
BATTERY ALARM
CAM RCV Level
CCU RCV Level
VER.
p CABLE OPEN
This item flashes when the optical fibre multi cable is not
connected.
p CABLE SHORT
This item flashes when the optical fibre multi cable is
short-circuited.
p FAN ALARM
This item flashes when the unit's fan has shut down.
p BATTERY ALARM
This item flashes when something is wrong with the unit's
voltage.
p CAM RCV Level
The level of the optical signals received by the camera is
displayed in 5 gradations.
Level: wtttt to wwwww
p CCU RCV Level
The level of the optical signals received by the unit is
displayed in 5 gradations.
Level: wtttt to wwwww
p VER.
The unit's software version is displayed here.