General Specifications
Surroundings
Enclosure, frame size D and E
Enclosure, frame size F
Vibration test
Max. relative humidity
Aggressive environment (IEC 60068-2-43
Ambient temperature (with SFAVM switching mode)
- with derating
- at full continuous drive output current
1) For more information on derating, see special conditions in the Design Guide
Minimum ambient temperature during full-scale operation
5
5
Minimum ambient temperature at reduced performance
Temperature during storage/transport
Maximum altitude above sea level without derating
Derating for high altitude, see special conditions in the Design Guide
EMC standards, Emission
EMC standards, Immunity
See section on special conditions in the Design Guide.
Protection and Features
Electronic thermal motor protection against overload.
Temperature monitoring of the heatsink ensures that the frequency converter trips if the temperature reaches a
predefined level. An overload temperature cannot be reset until the temperature of the heatsink is below the
values stated in the tables on the following pages (Guideline - these temperatures may vary for different power
sizes, frame sizes, enclosure ratings etc.).
The frequency converter is protected against short-circuits on motor terminals U, V, W.
If a mains phase is missing, the frequency converter trips or issues a warning (depending on the load).
Monitoring of the intermediate circuit voltage ensures that the frequency converter trips if the intermediate circuit
voltage is too low or too high.
The frequency converter constantly checks for critical levels of internal temperature, load current, high voltage on
the intermediate circuit and low motor speeds. As a response to a critical level, the frequency converter can adjust
the switching frequency and/ or change the switching pattern to ensure the performance of the frequency
converter.
94
®
VLT
Automation Drive FC 300 Operating Instructions
5% - 95%(IEC 721-3-3; Class 3K3 (non-condensing) during operation
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
MG33U402 - Rev. 2013-12-16
IP 00/ Chassis, IP 21/ Type 1, IP 54/ Type 12
IP 21/ Type 1, IP 54/ Type 12
-25 - +65/70 °C
EN 61800-3, EN 61000-6-3/4, EN 55011
EN 61800-3, EN 61000-6-1/2,
0.7 g
class H
5
2
1)
Max. 55 °C
Max. 45 °C
1)
0 °C
- 10 °C
1000 m