Complete the following steps:
1. Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A6 [I.580A6] : Memory spare copy has completed successfully. Spare Copy Complete
Severity
Info
User Response
Complete the following steps:
1. Check system log for related DIMM failures and replace those DIMMs.
• S.1100B [S.1100B] : CATERR(IERR) has asserted on processor %.
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or UEFI firmware update that applies
to this Processor error.
2. Reboot system. If problem persists escalate to the next level of support.
• S.1100C [S.1100C] : An uncorrectable error has been detected on processor %.
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or UEFI firmware update that applies
to this error.
2. Reboot system. If problem persists escalate to the next level of support.
• S.2011000 [S.2011000] : An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
The Vendor ID for the device is % and the Device ID is %. PCI PERR Detected
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable device driver, firmware update, revision of service
information for this product or other information that applies to this error. Load new device driver
and any required firmware updates.
2. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured
.
Chapter 6
Troubleshooting
927