Lenovo Flex System x480 X6 Compute Node Installation And Service Manual page 663

Hide thumbs Also See for Flex System x480 X6 Compute Node:
Table of Contents

Advertisement

Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Complete the following steps:
1. Check the CMM or FSM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
• 806f0a07-0301ffff : [ProcessorElementName] is operating in a Degraded State.
The processor is being throttled due to thermal or power conditions.
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - CPU
SNMP Trap ID
42
CIM Information
Prefix: PLAT ID: 0038
User Response
Complete the following steps:
1. Check the CMM or FSM event log for any fan- or cooling-related issues or power-related issues..
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• 806f0a07-0302ffff : [ProcessorElementName] is operating in a Degraded State.
.
Chapter 6
Troubleshooting
653