Lenovo Flex System x480 X6 Compute Node Installation And Service Manual page 459

Hide thumbs Also See for Flex System x480 X6 Compute Node:
Table of Contents

Advertisement

Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Information Center for the appropriate user response.
Related links
"Finding the UEFI diagnostic code" on page 919
806f030c-2007ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Memory error discovered during boot..(not a runtime error).
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Information Center for the appropriate user response.
Related links
"Finding the UEFI diagnostic code" on page 919
806f030c-200801ff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Memory error discovered during boot..(not a runtime error).
Severity
Error
.