in the new system board (see "Removing a microprocessor and heat sink" on page 1027 and
"Installing a microprocessor and heat sink" on page 1030).
• Solid state drives (see "Installing a solid state drive" on page 1021).
• Solid state drive cage and backplane (see "Installing the solid state drive cage and backplane"
on page 1023).
• Solid state drive mounting sleeves (see "Installing the solid state drive mounting sleeve" on
page 1024).
• USB flash drives (see "Installing the USB flash drive" on page 1026).
Step 2.
Install the left- and right-bezels (see "Installing the bezel" on page 980).
Step 3.
The replacement system-board assembly comes with a Repair Identification (RID) tag. Using a fine
tip indelible ink pen, transfer the machine type and serial number from the defective system-board
assembly to the label on the Repair Identification tag; then, place the tag in the recessed area 1 on
the bottom of replacement system-board assembly.
After you install the components on the system board of the new base assembly, complete the following
steps:
1. Install the cover onto the compute node (see "Installing the compute node cover" on page 988 for
instructions).