Lenovo Flex System x480 X6 Compute Node Installation And Service Manual page 502

Hide thumbs Also See for Flex System x480 X6 Compute Node:
Table of Contents

Advertisement

Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0170
User Response
Information only; no action is required.
• 806f0313-1701ffff : A software NMI has occurred on system [ComputerSystemElementName].
A software NMI has occurred. The compute node might have restarted, depending on the configuration
setting.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0228
User Response
Check the operating-system logs and resolve any issues related the NMI.
• 806f0323-2101ffff : Power cycle of system [ComputerSystemElementName] initiated by watchdog
[WatchdogElementName].
The IPMI watchdog timer has expired. The compute node has been powered off and powered on.
Severity
Info
Serviceable
No
Automatically notify support
No
492