Automatically notify support
No
Alert Category
System - Power On
SNMP Trap ID
24
CIM Information
Prefix: PLAT ID: 0107
User Response
Information only; no action is required.
•
816f000d-0400ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
Presence of drive 0 is no longer detected. If hard drive is absent from drive bay a filler is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
– If drive was intentionally removed, no action required.
– Make sure that the drive properly seated.
– If drive is properly seated, replace the drive.
•
816f000d-0401ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
Presence of drive 1 is no longer detected. If hard drive is absent from drive bay a filler is required.
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
720
Lenovo Flex System x280 X6, x480 X6, and x880 X6 Compute Node Installation and Service Guide