Lenovo Flex System x480 X6 Compute Node Installation And Service Manual page 578

Hide thumbs Also See for Flex System x480 X6 Compute Node:
Table of Contents

Advertisement

SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
– Replace the hard disk drives that are indicated by a lit status LED on the drive.
– Recreate the array.
– Restore data from backup.
806f070c-2001ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
A Memory DIMM configuration error has been detected.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Information Center for the appropriate user response.
Related links
"Finding the UEFI diagnostic code" on page 919
806f070c-2002ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
A Memory DIMM configuration error has been detected.
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
568
Lenovo Flex System x280 X6, x480 X6, and x880 X6 Compute Node Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents