Electrical Connections; Process Connections - Emerson Rosemount 3051S Manual Supplement

Hide thumbs Also See for Rosemount 3051S:
Table of Contents

Advertisement

Manual Supplement
00809-0100-4851, Rev AA
8.3.2

Electrical connections

/
–14 NPT, G
1
2
code A and X.
8.3.3

Process connections

Autoclave connection or seals
8.3.4
Process-wetted parts
Process isolating diaphragms
Coplanar sensor module
Alloy C-276 (UNS N10276)
8.3.5
Non-wetted parts
Electronics housing
Low-copper aluminum alloy or CF-8M (Cast 316 SST)
Enclosures meet NEMA
Note
IP 68 is not available with wireless output.
Coplanar sensor module housing
C-276 module base, CF-3M (Cast 316L SST) upper module housing
8.3.6
Sensor module fill fluid
Silicone is standard.
8.3.7
Paint for aluminum housing
Polyurethane
8.3.8
Cover O-rings
Buna-N
8.3.9
Wireless antenna
External antenna (WK/WM)
PBT/PC integrated omni-directional antenna
Rosemount 3051S High Pressure
/
, and M20 x 1
/
conduit. HART interface connections fixed to terminal block for output
1
1
2
2
®
Type 4X, IP66, and IP68 [66 ft (20 m) for 168 hours] when properly installed.
Rosemount 3051S High Pressure
2017
37