Select application "Level
measurement"
Select adjustment unit/den-
sity unit
VEGABAR 54 - 4 ... 20 mA/HART
Setup with the indicating and adjustment module PLICSCOM
You can find these data on the type label on the instrument and
in the menu items of the min./max. adjustment.
PLICSCOM enables the adjustment without filling or pressure.
You can carry out the settings in the workshop without the
instrument having to be installed.
Also the current measured value is shown in the menu items
for the min./max. adjustment.
VEGABAR 54 is preset to application "Process pressure
measurement". Proceed as follows when switching over to
application "Level measurement":
1 Push the [OK] button in the measured value display, the
menu overview is displayed.
2 Select the menu Service with "[–>]" and confirm with [OK].
Basic adjustment
Display
Diagnostics
Service
Info
3 Select the menu item "Application" with [–>] and edit with
[OK].
Warning:
Note the warning: "Output can change".
4 Select "OK" with [–>] "OK" and confirm with [OK].
5 Select "Level" from the list and confirm with [OK].
To switch over to another adjustment unit (in the example from
bar to mbar), proceed as follows:
1 Push the [OK] button in the measured value display, the
menu overview is displayed.
Basic adjustment
Display
Diagnostics
Service
Info
2 Confirm the menu "Basic adjustment" with [OK], the
menu item "Units of measurement" will be displayed.
Selection options: mbar, bar, psi, Pa, kPa, MPa, inHg, mmHg, inH
9)
mmH
O, mm, cm, m, in, ft.
2
9)
O,
2
39