As shipped
400V
200V
Power Connectors (optional)
Must terminate the power connector terminal
block correctly to ensure 200VAC-240VAC
output. Line cord provided for connection
to projector only.
Power Connector Breaker
(On = up position)
1. Connect the LPS Communication Cables:
a. Remove the 2 cover plate thumbscrews from the projector's baseplate in the LVPS compartment.
b. Connect one end of the RS232 cable to the port on the LPS labeled RS232. Route the cable up through
the opening in the projector's baseplate into the LVPS compartment. Connect the other end of the
RS232 cable to the port labeled RS232 in the LVPS compartment.
c. Connect one end of the Interlock cable to the port on the LPS labeled Interlocks. Route the cable up
through the opening in the projector's baseplate that you ran the RS232 cable. Connect the other end of
the Interlock cable to the port labeled Interlock in the LVPS compartment.
D4K35 Setup Guide
020-100855-02 Rev. 1 (09-2014)
3
LPS Breaker
Phase Status LEDs
4.
Figure 2-22 Connect LPS
Configure the LPS for incoming AC
NOTE: Internal
Input Line Voltage
switch setting
must match AC available at the site.
Power Connector
Terminal Block
AC Input
Terminal Block
Earth Ground
Connect to 3-phase AC supply:
• 208 VAC in N. America
• 200 VAC in Japan
• 380-415 VAC in Europe
Line cord not supplied. Must supply
appropriate strain relief.
Section 2: Installation and Setup
Interlocks
Connect communication
1
cables to projector
(inside LVPS compartment)
RS232
+ DC
Connect lamp leads
2
– DC
to projector (to igniter)
2-17