FUSING UNIT
NOTE: 2) When re-installing the thermistor, thermofuse, and lamps, secure all
harnesses in the clamps [A] correctly and do not locate them in the
area indicated as 'NG' [B].
3) When re-installing the lamps, check that the grounding brush [C]
contacts the hot roller [D].
4) When re-installing the lamps, check that they are installed correctly,
and that they can move slightly from front to rear.
A229
[A]
A229R651.WMF
5-86
[B]
[NG]
[C]
[D]