SERVICE PROGRAM MODE
Mode No.
(Class 1 , 2 & & & & 3)
2-965
Toner Pump Adjustment
6
Aggregate of
Toner Waste
3-001
ID Sensor PWM Setting
ID Sensor
1
PWM Setting
2
Initialization
3-103
ID Sensor Output Display
3-901
Auto Process Control
3-902
Process Control Data Display
1
Auto Process
Control
2
V
D
3
Half Tone V
4
V
G
5
LD Power
(Correction)
6
V
ID
A229
*
Factory use only
Use this SP mode when an SC condition
*
occurs because ID Sensor Initial Setting
was not done after doing an NVRAM Clear
or replacing the NVRAM. Reset this SP to
the factory setting in this case.
The PWM data is stored when ID Sensor
Initial Setting is done.
*
Performs the ID sensor initial setting. The
ID sensor output for the bare drum (V
adjusted to 4.0 ± 0.2V.
This SP mode should be performed after:
1. Replacing or cleaning the ID sensor
2. Replacing the NVRAM or doing an
NVRAM clear
3. Replacing the SBICU board
*
Displays the current V
V
= x.xx V
SP
V
= x.xx V
SG
If the ID sensor does not detect the ID
pattern, "V
SP
and an SC code is generated.
If the ID sensor does not detect the bare
area of the drum, "V
displayed and an SC code is generated.
*
Decides whether or not the machine
checks and corrects the drum potential
(V
) and LD power when the fusing
D
temperature is lower than 100°C at power-
up.
*
Displays whether auto process control is
on or off.
(O: OFF, 1: ON)
*
Displays the drum potential.
Displays the drum potential in areas
*
H
illuminated by the laser.
*
Displays the charge grid voltage which
resulted from the latest V
*
Displays the LD power correction value
which resulted from the latest V
adjustment.
*
Displays the latest drum surface voltage
measured on the ID sensor pattern.
4-20
Function
and V
output.
SG
SP
=5.0V/V
=5.0V" is displayed
SG
=0.0V/V
=0.0V" is
SP
SG
adjustment.
D
H
Settings
0 ~ 255
1/step
90
Start
) is
SG
ON
OFF
SM