Heat/Defog System Leak Check Functional Test - MD Helicopters MD Explorer Servicing And Maintenance

Table of Contents

Advertisement

CSP−900RMM−2
2. Heat/Defog System Leak Check
Functional Test
(Ref. Figure 601, Figure 602, and Figure 603)
Consumable Materials
(Ref. CSP−SPM)
Item
Nomenclature
C809
Leak Detector, Liquid
C220
Compound, Anti−Seize
Special Tools
(Ref. CSP−SPM)
Item
Nomenclature
Air Flow Measurement Test Set (Ref.
Figure 603)
(1). Open L260 and R260 (Ref. Section
06-00-00).
(2). Remove right aft station 230.00
bulkhead baggage compartment
interior trim insulation panels (Ref.
Section 25-50-00).
(3). Remove AR165, AR138, and AR129
(Ref. Section 06-00-00).
(4). Disconnect hose (5) and install AN
806J-12 plug in coupling nut (Ref.
Figure 602).
(5). Disconnect hose (4) and install
AN919-18J reducer in coupling nut
(Ref. Figure 602).
(6). Set HEAT switch on utility panel to
OFF.
(7). Make sure cabin flow control valve and
crew compartment heat/defog valve are
closed.
(8). Connect a test fixture as shown in
Figure 603.
(9). Apply regulated shop air 90-110 psig
(620.5-758.5 kPa) to air supply
adapter.
(10). With a constant pressure of 90-110
psig (620.5-758.5 kPa), check the air
Page 606
Revision 28
MD Helicopters, Inc.
Rotorcraft Maintenance Manual
21-40-00
flow rate. Air flow rate must be less
than 2.0 cfm (56.6 L/m).
(11). If the air flow rate is more than 2.0 cfm
(56.6 L/m), continue functional test as
follows:
(a). check all tube connections and
fittings above the engine deck for
leaks.
(b). Apply liquid leak detector (C809) to
the flow control shutoff valve,
firewall fittings, main bleed air
fitting, and tube and hose connectors.
(c). Make sure there are no air leaks
around the flow control shutoff valve,
firewall fittings, main bleed air
fitting, and tube and hose connectors.
(d). If necessary, repair air leaks.
(12). If air flow rate is less than 2.0 cfm
(56.6 L/m), continue functional test as
follows:
(a). Set POWER switch on ELEC­
TRICAL MASTER panel to BAT/
EXT.
(b). Set HEAT switch on utility panel to
OVRD.
(c). Air flow rate must be less than 4.0
cfm (113.2 L/m).
(13). If air flow rate is more than 4.0 cfm
(113.2 L/m), continue functional test as
follows:
(a). Check all tube connections and
fittings for leaks.
(b). Apply liquid leak detector (C809) to
tube connectors and fittings.
(c). Make sure there are no air leaks at
tube connections and fittings.
(d). If necessary, repair air leaks.
(14). If air flow is less than 4.0 cfm (113.2
L/m), continue functional test as
follows:
(a). Manually operate flow control valve
to make sure aft cabin heat ejector
control cable is adjusted correctly.