Installation On Pedestal - Danfoss vlt aqua Design Manual

Hide thumbs Also See for vlt aqua:
Table of Contents

Advertisement

®
VLT
AQUA Drive Design Guide

3.7.3 Installation on Pedestal

This section describes the installation of a pedestal unit available for the
adjustable frequency drives frames D1 and D2. This is an 8 in [200 mm]
high pedestal that allows these frames to be floor mounted. The front of
the pedestal has openings for input air to the power components.
The adjustable frequency drive connector plate must be installed to pro-
vide adequate cooling air to the control components of the adjustable
frequency drive via the door fan and to maintain the IP21/NEMA 1 or
IP54/NEMA 12 degrees of enclosure protections.
There is one pedestal that fits both frames D1 and D2. Its ordering number is 176F1827. The pedestal is standard for E1 frame.
Required Tools:
Socket wrench with 0.28–0.67 in [7–17 mm] sockets
T30 Torx Driver
Torques:
M6 - 4.0 Nm (35 in-lbs)
M8 - 9.8 Nm (85 in-lbs)
M10 - 19.6 Nm (170 in-lbs)
Kit Contents:
Pedestal parts
Instruction Manual
®
MG.20.N5.22 - VLT
is a registered Danfoss trademark
Figure 3.32: Drive on pedestal
Figure 3.33: Mount the drive onto pedestal.
3 VLT AQUA Selection
3
3-51

Advertisement

Table of Contents
loading