User Interface

5.1.2 Setting LCP Display Values

The display area is activated when the frequency converter
receives power from mains voltage, a DC bus terminal, or
an external 24 V DC supply.
The information displayed on the LCP can be customized
for user application.
Each display readout has a parameter associated
with it
Options are selected in the quick menu Q3-13
Display Settings
Display 2 has an alternate larger display option
The frequency converter status at the bottom line
of the display is generated automatically and is
not selectable
Status
799 RPM
1.1
1.2
Auto Remote Ramping
2
3
Illustration 5.2 Display Readouts
Status
207RPM
1.1
Auto Remote Running
Illustration 5.3 Display Readouts
MG16D302
Operating Instructions
1 (1)
7.83 A
36.4 kw
0.000
53.2 %
1.3
1 (1)
5.25A
24.4 kW
6.9
Hz
1.3
1.2
2
Danfoss A/S © Rev. 06/2014 All rights reserved.

5.1.3 Display Menu Keys

Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
Quick
Status
Menu
Illustration 5.4 Menu Keys
Key
Function
Status
Shows operational information.
In Auto mode, press to toggle between
status readout displays.
Press repeatedly to scroll through each
status display.
Press [Status] plus [
display brightness.
The symbol in the upper right corner of the
display shows the direction of motor
rotation and which set-up is active. This is
not programmable.
Quick Menu
Allows access to programming parameters for
initial set-up instructions and many detailed
application instructions.
Press to access Q2 Quick Set-up for
sequenced instructions to program the basic
frequency controller set-up.
Follow the sequence of parameters as
presented for the function set-up.
Main Menu
Allows access to all programming parameters.
Press twice to access top-level index.
Press once to return to the last location
accessed.
Press to enter a parameter number for
direct access to that parameter.
Alarm Log
Displays a list of current warnings, the last 10
alarms, and the maintenance log.
For details about the frequency converter
before it entered the alarm mode, select the
alarm number using the navigation keys
and press [OK].
Table 5.1 Function Description Menu Keys
Main
Alarm
Menu
Log