Lenovo x3550 M5 Installation And Service Manual page 621

Hide thumbs Also See for x3550 M5:
Table of Contents

Advertisement

CIM Information
Prefix: PLAT ID: 0142
User Response
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-2010ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 16)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2010ffff or 0x806f090c2010ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-2011ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 17)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2011ffff or 0x806f090c2011ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
607

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents