Table of Contents

Advertisement

3. Manually re-enable all affected DIMMs.
4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
5. If the problem follows the DIMM, replace the failing DIMM.
6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
7. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
8. (Trained technician only) Replace the affected microprocessor.
One of the DIMMs :
• 806f030d-0400ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 0)
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
May also be shown as 806f030d0400ffff or 0x806f030d0400ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0170
User Response
No action; information only.
• 806f030d-0401ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 1)
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
May also be shown as 806f030d0401ffff or 0x806f030d0401ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
507