Lenovo x3550 M5 Installation And Service Manual page 700

Hide thumbs Also See for x3550 M5:
Table of Contents

Advertisement

This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040affff or 0x816f000d040affff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000d-040bffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 11)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040bffff or 0x816f000d040bffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
686
Lenovo System x3550 M5 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents