Teac GX-1 Instruction Manual page 84

Integrated recorder
Table of Contents

Advertisement

Specifications
Number of channels :
2
Input format :
Unbalanced
Input coupling :
DC
Input impedance :
100 kΩ
Input range :
±0.5, 1, 2, 5, 10, 20 Vp
Range accuracy:
±1% or better
Frequency response :
DC to 80 kHz (±1.5 dB)
Low pass filter :
2, 4, 8, 20, 40, 80, 200, 400, 800 Hz,
2 k, 4 k, 8 k, 20 k, 40 k, 80 kHz
±1.5 dB at the cutoff frequency
Attenuation: –48 dB/oct
Linearity:
±0.1% or better
S/N ratio:
71 dB (typical), 65 dB or better (sampling fre-
quency: 50 kHz; input range: 1 V; LPF: 20 kHz)
A/D converter :
16-bit
Sampling frequency :
1 Hz to 200 kHz
Power consumption :
Approx. 2.16 W
Input connector :
BNC
Settings
The following dialog box appears when you choose Setup and Params, and
then double-click the channel that you want to set.
Channel :
Select ENABLE to record with this channel, or select DIS-
ABLE not to record with this channel.
Range :
Select the input range.
Sample Frequency : You can select 10 times the Base Sample Freq
when you turn on Multi Sampling check box.
Channel Name : You can name the channel. Use up to 16 alphanumeric
characters.
Filter :
Select the filter cutoff frequency.
All DC Amp Same Condition : When this option is selected, the same
parameters are set for all signal conditioners of the same type.
Enable both channels of a slot.
Filter cutoff frequency is set slot by slot, not channel
by channel.
Amplifiers
4-17

Advertisement

Table of Contents
loading

Table of Contents