Specifications
Signal conditioner slots :
Recording device slot :
Memory :
Interface :
Contact-point control :
Expansion bus connector :
DIGITAL CONTROL connector :
Monitor channel analog output :
Microphone jack :
Speaker/earphone jack :
Sampling frequencies:
Internal clock :
Multi-sampling :
External clock :
Power :
Power consumption :
Operating temperature :
Storage temperature :
Operating humidity :
Vibration :
External dimensions :
Mass:
Specifications when AIT drive installed
Power consumption :
Operating temperature :
Storage temperature :
Vibration :
Mass:
Specifications when MO/PC card drive installed
Power consumption :
Operating temperature :
Storage temperature :
Mass:
Specifications are subject to change without notice.
4-4

Specifications for the GX-1 Main Unit

8
1 (for AIT drive)
DIMM 32—256 MB
SCSI (connector 50-pin half size x 1, built-in terminator)
START, STOP, EVENT, REC STANDBY
1 (common)
1 (time code, external sampling clock input)
1 (no filter, output level fixed to ±5 V)
1
1 each
1, 2, 5, 10, 20, 50, 100, 200, 500 Hz
1, 2, 5, 10, 20, 50, 100, 200, 2.5, 12.5, 25 kHz
From the internal clock frequencies, you can select a base sampling
frequency and 10 times the base sampling frequency slot by slot at a
time.
Up to the maximum sampling frequency of each signal conditioner
Note: The total of [sampling-frequency x number-of-channels] must
not exceed 3,200 kHz.
+11 to 30 V DC
Built-in AC adaptor: for 100 V: 90 to 130 V, 50 to 400 Hz
Battery (option)
Approx. 45 W (DC power supply, w/ 8 DC input amps, w/o drive)
Approx. 75 W (Using AC adaptor, w/ 8 DC input amps, w/o drive)
0 to 40ºC (32 to 104ºF)
–20 to 60ºC (–4 to 140ºF)
20 to 80% RH (non-condensing)
MIL-STD-810D Figure 514.3-1, 2, 3
Approx. 300W x 85H x 200D (mm) (excluding protruding parts)
Approx. 5 kg (including 8 DC input amps and an AC adaptor)
Approx. 58 W (w/ DC input amp for all channels)
5 to 35ºC (41 to 95ºF)
–20 to 60ºC (–4 to 140ºF)
MIL-STD-810C Figure 514.2-6 V Curve (1.5G, vertical)
Approx. 5.75 kg (including 8 DC input amps and an AC adaptor)
Approx. 52 W (w/ DC input amp for all channels)
5 to 35ºC (41 to 95ºF)
–20 to 60ºC (–4 to 140ºF)
Approx. 5.5 kg (including 8 DC input amps and an AC adaptor)
for 200 V: 180 to 260 V, 50 to 400 Hz

Advertisement