Are Rx-Iq Signal Waveforms And Levels Correct - Nokia 6680 RM-36 Service Manual

Mobile terminal
Table of Contents

Advertisement

Appendix A: RF Troubleshooting
GSM1800: C7581, C7584 and L7505
GSM1900: C7523, C7525 and L7506
Check that components are in place and solder joints are ok
Use an ohmmeter to check that inductors are conducting DC.
Replace matching components

3.2.2 Are RX-IQ signal waveforms and levels correct?

Measurements can be done with an oscilloscope, a probe and signal generator.
GSM receiver has to be active before RX IQ-signals can be measured. Procedure is explained in
section "GSM RX chain activation for manual measurements".
Apply –70 dBm RF signal from a signal generator to the module jig antenna connector and use
following frequencies:
EGSM900: 942.46771 MHz (Channel 37)
-
GSM1800: 1842.86771 MHz (Channel 700)
-
GSM1900: 1960.06771 MHz (Channel 661)
-
Remember to change correct RX channels also to Phoenix "RF controls" window!
Check RX I and RX Q -signals in following test points:
RX I (positive): Connect the probe to test point J7508
-
RX I (negative): Connect the probe to test point J7509
-
RX Q (positive): Connect the probe to test point J7510
-
RX Q (negative): Connect the probe to test point J7511
-
The correct RX IQ-signal is shown in figure
signals should be about the same and RX IQ-signal frequency should be 67.71 kHz (lower detail
figure). The phase shift between I- and Q-signals should be 90 degrees.
3.2.2.1 RF operating voltage VBAT_ASIC ok?
See section
3.2.2.2 RFBUS signals ok?
GSM receiver has to be active before RFBUS signals can be measured. Procedure is explained in
section "GSM RX chain activation for manual measurements". Also WCDMA/GSM transmitter and
WCDMA receiver activation can be used for the measurement but then RFBUS -signals don't
necessarily look like in figures mentioned below.
Measurements can be performed with an oscilloscope and a probe. Check all five RF BUS signals:
RFBUSDAT: Connect the probe to J7504. Typical RFBUSDAT -signal is shown in figures in section
-
6.5.9.3 "RFBUSDAT (GSM
"RF operating voltage VBAT_ASIC ok?"
RX)".
Company Confidential
Copyright © 2005 Nokia. All rights reserved
6.5.6 "GSM RX IQ (DC Offset 0.4
Nokia Customer Care
V)". Level of all four IQ-
A-51

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents