Nokia 6680 RM-36 Service Manual page 333

Mobile terminal
Table of Contents

Advertisement

Appendix A: RF Troubleshooting
and VBW = 1 MHz, Span ≤ 200 kHz.
Check the level of the VCO frequency in T7503 outputs. The level should be about -30...-35 dBm in
both output lines. If the signal level is correct in the input (about -25 dBm) but output level is not
as expected then replace T7503. VCO shield has to be removed before measurement. Remember to
solder the shield back after the phone repairing.
4.1.2.1.6.1 TX VCO G7502 output level high enough?
WCDMA transmitter has to be active before TX VCO's output frequency and output level can be
measured. Procedure is explained in section "Transmitter troubleshooting".
Measurements can be done with a spectrum analyser and an RF probe. Spectrum analyser centre
frequency should be set according the used TX channel (see section "Frequency mappings"). RBW
and VBW = 1 MHz, Span ≤ 200 kHz.
Connect the RF probe to the T7503 input. VCO shield has to be removed before measurement.
Remember to solder the shield back after the phone repairing.
Check if the frequency of the TX VCO is as expected. If the VCO signal is not found try to use wider
span setting. The output level of the VCO should be about -25 dBm.
4.1.2.1.6.1.1 Replace TX VCO G7502
4.1.2.1.6.2 Replace balun T7503
4.1.2.1.7 Replace Vinku (N7501)
4.1.2.2 Is there correct RF-power in the WCDMA PA (N7503) input?
WCDMA transmitter has to be active before measurements. Procedure is explained in section
"Transmitter troubleshooting".
Set TX power level to 0 dBm (Set start level "0" to Phoenix)
Measurements can be done with a spectrum analyser and an RF probe. Remember to make correct
frequency setting to the spectrum analyser. Spectrum analyser centre frequency should be set
according the used TX channel (see section "Frequency mappings").
Spectrum analyser RBW = VBW = 10 MHz, Span ≤ 2 MHz, sweep time 100 ms.
Connect the probe to Z7506 output. The RF level should be roughly -40...-48 dBm.
4.1.2.2.1 Is Vinku (N7501) output RF-signal coming correctly to the Z7506 (SAW filter)?
WCDMA transmitter has to be active before measurements. Procedure is explained in section
"Transmitter troubleshooting".
Set TX power level to 0 dBm (Set start level "0" to Phoenix)
Measurements can be done with a spectrum analyser and an RF probe. Spectrum analyser centre
frequency should be set according the used TX channel (see section "Frequency mappings").
Company Confidential
Copyright © 2005 Nokia. All rights reserved
Nokia Customer Care
A-87

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents