Are Components In Gsm Power Control Loop In Place And Working Ok; Does Gsm Pa (N7502) Get Correct Bias Currents? Is The Level Of Bias Currents Ok - Nokia 6680 RM-36 Service Manual

Mobile terminal
Table of Contents

Advertisement

Nokia Customer Care
GSM1900:
Offset (kHz)
Limit (dBc)
One example of measured GSM Modulation Spectrum in EGSM900 band is presented in figure
"TX Modulation spectrum
If modulation spectrum is not as expected separate the phone into parts and place to the
module jig (Notice that there are three antenna connectors in the module jig, one for GSM, one
for WCDMA and one for Bluetooth. Make sure that all connections are made to the correct RF-
connector).

3.4.1 Are components in GSM power control loop in place and working ok?

R7516 and C7559
Disconnect the power supply from the phone and use an ohmmeter to check that C7559 is not
short-circuited. If short-circuit is found replace the capacitor. Check R7516 resistance value with an
ohmmeter and replace resistor if needed.

3.4.2 Does GSM PA (N7502) get correct bias currents? Is the level of bias currents ok?

EGSM: Icont_21 and Icont_22
GSM1800/GSM1900: Icont_31 and Icont_32
GSM transmitter has to be active before measurements. Procedure is explained in section
"Transmitter troubleshooting".
Set TX power level to the maximum ("5" in EGSM900 and "0" in GSM1800/GSM1900)
Measurements can be done with an oscilloscope and a VOLTAGE probe.
EGSM900:
Connect the probe to C7545 or C7544. Notice: C7544 is a non-assembled component so the probe
-
should be connected to the pad that can be still found from the PWB
Typical full TX power bias currents (Icont_21 and Icont_22) should look somehow similar to figure
-
6.5.4
Check both currents.
GSM1800 or GSM1900:
Connect the probe to C7561 or C7556. Notice: C7556 is a non-assembled component so the probe
-
should be connected to the pad that can be still found from the PWB
Typical full TX power bias currents (Icont_31 and Icont_32) should look somehow similar to figure
6.5.5 "Icont_31/Icont_32 (DC Offset 1.2 V)"
A-66
100
200
+0,5
-30
(GSM)"..
"Icont_21/Icont_22 (DC Offset 1.2 V)", when measured with an oscilloscope and a probe.
Copyright © 2005 Nokia. All rights reserved
250
400
-33
-60
when measured with an oscilloscope and a probe. Check
Company Confidential
Appendix A: RF Troubleshooting
600
1 200
< 1 200
< 1 800
-60
-60
6.5.8

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents