Nokia 6680 RM-36 Service Manual page 242

Mobile terminal
Table of Contents

Advertisement

Nokia Customer Care
18. Select the Algorithm mode tab.
19. Write the target power level 25 dBm to the "Start level" line and check the "Max power limit" check box
(detector calibration check).
20. Setup the spectrum analyzer with the following settings:
Center frequency:
Span:
Reference level offset:
Reference level:
Input attenuation:
Resolution bandwidth:
Video bandwidth:
Sweep time:
Detector:
Average:
Trigger:
21. Click Send.
Page 7–54
Company Confidential
Copyright ©2005 Nokia. All Rights Reserved.
RF Troubleshooting and Manual Tuning Guide
1950.0 MHz
0 Hz
Cable attenuations + adapter attenuation
24 dBm or -20 dBm depending on the level
measured
Automatic
5 MHz
5 MHz
20 ms
RMS detector
No
Free run
RM-36
Issue 1