Electrical connection

NOTE! The boiler must be filled with water before the wiring begins.
NOTE! There is a ground cable in the motherboard cover.
For wiring to the motherboard you need to use a standard
screwdriver with a tip width of 3mm and a length of about
12cm. You can open the spring load of the motherboard in
both the tracks that are on every cable entry.
When it's time to do the electrical connection you need to remove the front casing which
is in front of the motherboard. Note that there is a ground cable in the cover. On the back-
side of the boiler there are four (1) conduits that end in the
front of the boiler (2). These are used to connect the sensors
and electrical cables. Don't put the low and high voltage in
the same hose. To remove the front casing. remove the two
screws(3), then pull it free using the handles.
Then connect the input voltage to the card's ports, according
to wiring diagram on previous page.
Current sensors
If your electrical system has a problem
providing enough electricity to the elec-
trical heater and the house at the same
time you can install current sensors that
lower the power to the electrical heater
if its necessary. This is done by distribu-
ting the power to the building's different
phases.
Connection of current sensors
To measure the power you must install
one current sensor to each incoming
phase in the house. This must be done
directly in the electrical contral. Connect
the sensors to a cable with the area
of 0,5mm2 to the circuit board. In the
"electrical heater" menu you set the max
power that's allowed on the fuses in your
house.
Effecta AB Västra Rågdalsvägen 21 434 99 Kungsbacka Sweden +46-300 - 22320 info@effecta.se
VARNING LIVSFARLIG SPÄNNING
WARNING DANGEROUS
VOLTAGE
E SPANNUNG
ACHTUNG GEFÄHRLICH
DANGEREUSE
AVERTISSEM ENT TENSION
VARNING LIVSFARLIG SPÄNNING
VOLTAGE
WARNING DANGEROUS
E SPANNUNG
ACHTUNG GEFÄHRLICH
DANGEREUSE
AVERTISSEM ENT TENSION
VARNING LIVSFARLIG SPÄNNING
VOLTAGE
WARNING DANGEROUS
E SPANNUNG
ACHTUNG GEFÄHRLICH
AVERTISSEM ENT TENSION
DANGEREUSE
17

Advertisement

Table of Contents
loading

Table of Contents