Menu system
Boiler temp
Fluetemp
El. heater
Acc. tank high G6
Acc. tank low G5
Room temp
Status
FV ---%
Operation
Heating System
Other
Burner
Fan
Feeder settings
Temperature set
Information
Service
Installation
Fan
Fan highspeed
Flue fan
Fan lowspeed
Fan alarm
Fan alarm
Tacho
Fan alarm
5s
Feeder settings
Start dose
Support dose
Pellets diameter
Run start dose
Run supp. dose
Run oper. dose
Temperature set
Boiler temp G1
Stop temp.
Start temp.
Acc.tank high G6
Acc.tank low G5
Stop G5
Max G6
Start G1
Loading pump Start
Loading pump Stop
Effecta AB Västra Rågdalsvägen 21 434 99 Kungsbacka Sweden +46-300 - 22320 info@effecta.se
Current boiler temp. G1
Current temperature of the flue gases G2
Current effect of the electrical heater in the boiler.
Current temp of the acc. tank top. (Only shown when sensor is installed)
Current temp of the acc. tank bottom. (Only shown when sensor is installed)
Current room temperature. (Only shown when installed and activated in software.)
Current burner mode. (Ignition-Running-Cooling-Standby-Off)
Current strength (brightness) of flame in boiler.
Settings for burner.
Settings for heating systems.
Remaining settings.
Burner mode (on/off)
Settings for the fan of the burner.
Settings of the augers feeding control.
Settings for the burners operation temp.
Operations log of the burner.
Menu for burner service settings.
Settings for automatic cleaning etc.
Setting of the burner fan speed in full effect oper. mode.
Setting of flue fan. Must be 10% higher than burner fan
Setting of the fan speed in low effect oper. mode.
Set in mode OFF or Tacho
Activates Tacho mode
Time before alarm triggers
Start dose size, measured according to (page 23).
Size of support dose, dose is given between ignition and running mode.
Size of the pellet
Test run of start dose for measuring. Only available in burner mode off.
Test run of supp. dose for measuring. Only available in burner mode off.
Test run of operation dose for measuring. Only available in burner mode off.
Shows the boiler temp, start/stop sensor with overheating function.
Temperature when the burner goes to standby mode.
Temperature when the burner starts up from standby mode.
When loading acc. tank, sensor G6 is installed at the tank top of the primary
tank. The sensor starts the burner at set temp.
When loading acc. tank, sensor G5 is installed low or at the bottom of the
primary tank. The sensor stops the burner at set temp.
Temperature when burner stops.
Maximal allowed temperature G6, tank overheated.
Temperature when burner starts.
Temperature when loading pump starts
Time loading pump runs