Stick Arc Starting Procedure - Everlast PowerUltra 206Pi Setup And User Manual

Igbt dc multi-process pulsetig/stick/plasma cutter
Table of Contents

Advertisement

Section 3
Tapping Method
1. Turn on the power switch on the rear of the unit. Allow unit to cycle through its start up program.
2. Select the Stick mode with the TIG/Cut/Stick selector switch.
3. Make sure electrode holder is connected to the positive connector and the work clamp is connected to the
negative connector. Remember, this is the opposite connection required for TIG and plasma.
4. Select the desired amperage. Use the electrode diameter selection chart in this manual to determine the
approximate range of amps suitable for the rod size selected. Consult the welding electrode manufacturer's
recommendation for proper amperage range. Each manufacturer has specific recommendations for its elec-
trodes. Ultimately Amperage is determined by the electrode thickness and the thickness of the metal.
5. Strike the arc with either the tapping method or the match strike method. Beginners usually find that the
match strike method yields best results. Professionals tend to gravitate toward the tapping method be-
cause of its placement accuracy which helps prevent arc striking outside of the weld zone.
IMPORTANT: Do not weld in the TIG mode with the stick electrode holder still attached.
STICK OPERATION
STARTING METHODS
Basic theory and function
Scratch/Match Method
25