Parameter
Value
55
z – Time [sec] after the Brave picks up, before it commences a choice [range
1-5].
This time is different for each switchboard phone system, but
generally most operate within 2 seconds after a line is picked up.
Parameter
Value
56
h
After the choice finishes it will start counting CRT (control ringing tones),
if the number is higher than hh, then it will disconnect [range 04-99]. It
repeats the choice if the regime of dialling 2 groups of numbers is set.
Parameter
Value
500
501
502
x
Medium frequency of tone detector is set if there is a non-standard signal
from the telephone switchboard.
y
Minimum number of busy tones necessary for detection [2-0], where 0
means 10 busy tones.
z
Minimum length of time of a permanent tone (for detection of notification
tone at branch switchboard) [1-5 sec].
34
Meaning
z
Time before commencing a choice
Meaning
Number of rings before it disconnects
hh
Meaning
x
Medium frequency of tone detector
y
Number of busy tones
z
Time length of permanent tone
BRAVE SlimDP –
User and service manual
Basic
1
(1-5)
Basic
12
(04-99)
Basic
3
(375-
(1-0)
475Hz)
4
(2-0)
3 (3s)
(1-5)
frequency
x - choice
[Hz]
275-375
325-425
375-475
425-525
475-575
525-625
575-675
625-725
675-775
725-825
1
2
3
4
5
6
7
8
9
0