GE EntelliGuard G Installation, Operation And Maintenance Manual page 89

Power circuit breaker
Hide thumbs Also See for EntelliGuard G:
Table of Contents

Advertisement

ENGLISH
133 Second
134 Phase
135 Event Specific 1
136 Event Specific 2
137 Event 8
138 Year
139 Month
140 Date
141 Hour
142 Minute
143 Second
144 Phase
145 Event Specific 1
146 Event Specific 2
147 Event 9
148 Year
150 Date
151 Hour
152 Minute
153 Second
154 Phase
155 Event Specific 1
156 Event Specific 2
157 Event 10
158 Year
159 Month
160 Date
161 Hour
162 Minute
163 Second
164 Phase
165 Event Specific 1
166 Event Specific 2
167 Long Time Trip Count
168 Short Time Trip Count
169 Instantaneous Trip Count
170 Ground Fault Sum Trip Count
179 Shunt 1 Trip Count
180 Shunt 2 Trip Count
196 Software Rev
227 Breaker Position
228 Error Code Log
229 Error Code Log
230 Error Code Log
231 Error Code Log
232 Error Code Log
233 Error Code Log
234 Error Code Log
235 Error Code Log
236 Error Code Log
237 Error Code Log
238 Error Counter
239 Long Time pickup State
0-Not in Pickup, 1-Near Pickup, 2-In Pickup Read
------------------------------------------------------------------------------------------------------
Communication Parameters Function 5
Reg.
Parameter
Values
103 Save Real Time Clock Registers
104 Read Real Time Clock Registers
105 Save EPROM Data
107 Upload to BIM
108 Trip Breaker
109 Reduced Instantaneous
112 Relay 1 State
113 Relay 2 State
116 Clear All Events
117 Clear EPROM
118 Clear Energy Total
8 bit
Read
8 bit
Read
16 bit
Read
16 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
16 bit
Read
16 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
16 bit
Read
16 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
16 bit
Read
16 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
8 bit
Read
1-CLOSE, 0-OPEN
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
See Comment
Read
1 to 10
Read
-
-
-
-
0- Reset, 1- Trip
0- Off, 1- ON
0- Off, 1- ON
0- Off, 1- ON
-
-
-
TRIP UNIT
2.5.1 Registo de Comunicações
PORTUGUÊS
Parâmetros de Comunicação Função 2
Reg. Variável
Valor
5
Estado Relé 1
0- OFF, 1- ON
6
Estado Relé 2
0- OFF, 1- ON
9
Estado Entrada 1
0- OFF, 1- ON
10 Estado Entrada 2
0- OFF, 1- ON
27 Posição Disjuntor
0- OFF, 1- ON
34 Indicação Berço
0- OFF, 1- ON
35 Extraível
0- OFF, 1- ON
44 Fecho remoto
0- OFF, 1- ON
------------------------------------------------------------------------------------------------------
Parâmetros de Comunicação Função 3
Reg. Variável
Valor
2
Protecção GF Sum
0-Inactiva,
5
N.º de Pólos
0-3 Pólo,
7
Medidas totais
0-Inactiva,
8
Posição de Neutro
0-Inactiva,
10 Tempo Longo Protec.
0-Inactiva, 1-Activa
18 Agency Standard
0-UL, 1-IEC, 2-ANSI
19 Disjuntor tipo
8- EntelliGuard
20 Tipo Modelo GTU
4-GTU ACB
22 Sensor Corrente Calibre
1-150A
2-200A
3-225A
4-400A
5-600A
6-800 A
7-1000A
35 ZSI
0-Inactiva,
37 MCR Nível baixo 16 bits
---
38 MCR Nível alto 16 bits
---
39 HSISC Nível baixo 16 bits
---
40 HSICS Nível alto 16 bits
---
81 Instantâneo
0-Inactiva,
98 Disjuntor Número de série - Baixo 16 bit
99 Disjuntor Número de série - alto 16 bits
107 Reduzido Instantâneo
0- Inactiva,
202 EntelliGuard Ajuste Ie
0- Não definido
1- 250,
2 - 280,
3 - 315,
4 - 350,
5 - 400,
6 - 450,
7 - 500,
8 - 560,
9 - 605,
10- 610,
11- 615,
12 - 630,
13 - 720,
14 - 768,
15 - 776,
16 - 784,
17 - 800,
18 - 900,
19 - 960,
20- 970,
21- 980,
22 -1000,
206 Protecção Pólo Neutro
0-50%,
207 ZSI Combinação
0
1-GF
2-GF&ST
3-ST
208 PT Tensão primária
120- 600
209 PT Ligação
0- Ph-N
210 Protecção Password
0 to 20
211 Modbus Endereço escravo
8 bit value
213 Config. Comm.
0- 300-8N2
1- 600-8N2
2- 1200-8N2 9- 1200-8O1 16- 1200-8E1
EntelliGuard G
Ler/Escrever
Ler
Ler
Ler
Ler
Ler
Ler
Ler
Ler
Ler/Escrever
1-Activa
Ler
1- 4 Pólo
Ler
1-Activa
Ler
1-Activa
Ler
Ler
Ler
Ler
8-1200A
15-5000A
Ler
9-1600A
16-6000A
10-2000A
17-630A
11-2500A
18-1250A
12-3000A
19-6400A
13-3200A
20-Substituição Universal
14-4000A
1-GT-ST (Z),
2-GR-ST-Inst (T)
Ler
Ler
Ler
Ler
Ler
1-15X Seleccionáveis.
Ler
-
Ler
-
Ler
1-Activa
Ler
23 - 1125, 46 - 3072, Ler e Escrever
24 - 1196,
47 - 3104,
25 - 1210,
48 - 3136,
26 - 1225,
49 - 3200,
27 - 1250,
50- 3840,
28 - 1280,
51- 3880,
29 - 1440,
52 - 3920,
30- 1536,53 - 4000,
31- 1552,54 - 4800,
32 - 1568,
55 - 4850,
33 - 1600,
56 - 4900,
34 - 1800,
57 - 5000,
35 - 1920,
58 - 6144,
36 - 1940,
59 - 6208,
37 - 1960,
60- 6272,
38 - 2000,
61- 6400,
39 - 2250,
62 - 160,
40- 2400,63 - 180,
41- 2425,64 - 380,
42 - 2450,
65 - 385,
43 - 2500,
66 - 390,
44 - 2560,
45 - 2880,
1-63%, 2-100%
Ler/Escrever
Ler/Escrever
4-Instantaneous
5-GF and Inst
7-GF, ST and Inst
Ler/Escrever
1- Ph-Ph
Ler/Escrever
16- Bloquear 19- Desbloquear Ler/Escrever
Ler/Escrever
7- 300-8O1
14- 300-8E1 Ler/Escrever
8- 600-8O1
15- 600-8E1
2
.5
2-47

Hide quick links:

Advertisement

Table of Contents
loading