YASKAWA V1000 Installation Manual page 39

Tcp/ip
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

u
Network Monitor Page (Network Monitor)
The embedded network monitor page shows the status of the option network traffic and open
I/O connections.
Figure 22
Network Monitor
Msg Tx OK
Msg Rx OK
Current Connections
Control Connection Delta
Time
Msg Tx Dropped
Msg Rx Dropped
Collisions
Msg Tx Errors
Msg Rx Errors
Tx Retry
Note: Cumulative counters are reset when the power supply is cycled.
YASKAWA ELECTRIC TOBP C730600 59A V1000 Option Modbus TCP/IP Installation Manual
Figure 23 Network Monitor Page View
Table 13 Network Monitor Explanations
Cumulative number of messages transmit successfully from the option.
Cumulative number of messages received successfully to the option.
Current number of open connections.
The time between the last two writes to the Control register, MEMOBUS/Modbus
address 0001H.
Cumulative number of messages dropped due to output network buffer being full and
unable to hold the new message.
Cumulative number of messages dropped due to input network buffer being full and
unable to hold the new message.
Cumulative number of collisions (half duplex only) reported by the MAC/PHY (Media
Access Control/Physical Connection).
Cumulative number of transmit underruns and transmit stops reported by the MAC/PHY.
Cumulative number of receive overruns, receive stops, and receive error frames reported
by the MAC/PHY.
Cumulative number of transmits in which the 1st attempt was delayed due to busy
medium reported by the MAC/PHY.
Explanation
8 Web Interface
EN 39