Calculation Of Total Deviation (According To Din 16086) - Vega VEGABAR 66 Operating Instructions Manual

Foundation fieldbus
Table of Contents

Advertisement

8 Maintenance and fault rectification
Total deviation
Example
52
?
E113
Communication conflict
l
à Exchange the instrument or send it in for repair
8.3 Calculation of total deviation (according to
DIN 16086)
The total deviation F
total
accuracy F
and longterm stability F
perf
maximum practical deviation or utility error.
= F
+ F
F
total
perf
stab
2
= √((F
+ (F
F
)
)
perf
T
Kl
With the analogue signal output there is also the error of the current
output F
.
a
2
= √((F
+ (F
F
)
)
perf
T
Kl
With:
F
: Total deviation
l
total
F
: Basic accuracy
l
perf
F
: Long-term drift
l
stab
F
: Temperature coefficient (influence of medium or ambient
l
T
temperature)
F
: Deviation
l
Kl
F
: Error current output
l
a
Level measurement 1500 mmWs
Product temperature 40 °C, reference temperature 20 °C
Selected: VEGABAR 66 with measuring range 0.2 bar
Calculation ΔT: ΔT = 40 °C - 20 °C = 20 K
Calculation of the set Turn Down:
TD = 200 mbar/147 mbar, TD = 1.4
Basic accuracy digital output signal in percent:
2
= √((F
+ (F
F
)
)
T
Kl
perf
= 0.05 %/10 K x TD
F
T
= 0.1 %
F
Kl
= √((0.05 %/10 K x 20 K x 1.4)
F
perf
= 0.17 %
F
perf
Total deviation digital output signal in percent:
= F
+ F
F
total
perf
stab
= 0.1 %/year x TD
F
stab
according to DIN 16086 is the sum of basic
. F
stab
2
)
2
2
(+ F
)
)
a
2
)
2
+ (0.1 %)
VEGABAR 66 • Foundation Fieldbus
is also called
total
2
)

Advertisement

Table of Contents
loading