4 Mounting
18
4.5 Mounting steps with lock fitting
Fig. 9: Lock fitting
1
Upper hexagon
2
Fixing screw
3
Washer disk
4
Lower hexagon
5
Fixing screw
Mount VEGABAR 66 with lock fitting as follows:
1
Weld the welded socket G1½ A or 1½ NPT to the vessel top
2
Lower VEGABAR 66 through the welded socket.
3
Turn the lock fitting on the lower hexagon into the welded socket.
Use a resistant seal. Spanner width SW 41, torque max. 80 Nm.
4
Adjust the connection tube of VEGABAR 66 to the requested
height and hold it
5
Turn the upper hexagon into the lower hexagon. Spanner width
SW 41, torque max. 80 Nm. VEGABAR 66 is now temporarily hold
by the washer disc.
6
Tighten fixing screws (2) and (5) with an Allen wrench size 2.5.
Torque max. 7 Nm.
The fixing screws press lightly into the connection tube and fasten
VEGABAR 66 in this position