4. SPECIFICATION

Measurement Specification
Function
Range
LOOP
200Ω
2000Ω
PSC
2000A
Range
Function
Uc
Rated Voltage
(AC)
L-PE :
20Ω
230V
L-PE :
230V
L-L :
400V
L-PE :
230V
200A
L-L :
400V
L-PE :
230V
20kA
Rated Voltage
(AC)
L-PE :
100V
230V
Test
Current
3A
+10%
50Hz
-15%
15mA
+10%
50Hz
-15%
15mA
+10%
50Hz
-15%
+10%
50Hz
-15%
15mA
+10%
50Hz
-15%
3A
+10%
50Hz
-15%
Test
Current
max15mA
5mA only at
+10%
50Hz
I⊿n=10mA
-15%
― 9 ―
Accuracy
±(3%rdg+8dgt)
±(3%rdg+8dgt)
At L-L measurement:
±(3%rdg+12dgt)
±(3%rdg+8dgt)
PSC accuracy is a
derived from
measured loop
impedance
specification.
Accuracy
+5%∼+15%
±8dgt