Kyoritsu 8035
Static induction
3-phase AC70 to 1000V (voltage to earth, continuous sine wave)
45 to 66Hz
-10 to 50ºC, relative humidity 80% or less (no condensation)
-20 to 60ºC, relative humidity 80% or less (no condensation) (*1)
Altitude 2000m or less, Indoor use
IEC 61010-1
Measurement CAT.III 1000V/CAT.IV 600V
Pollution degree 2
IEC61010-031
IEC 61326-1,2-2(EMC standard)-
IEC 61557-1,7
IP40 (IEC60529)
AC6880V (rms 50/60Hz) for 5 sec between the tip of Measurement clip
and enclosure
10MΩ or more/ 1000V between the tip of Measurement clip and
enclosure
DC6V (size AA alkaline battery LR6 or equivalent 1.5V AA × 4pcs)
10 min after powering on the instrument
Power LED flashes at 4.0±0.2V or less (*2)
15mA (*3)
approx. 200 hours (*4)
External diameter of the covered conductor Dia.2.4 to 30mm
approx. 70cm
112(L) × 61(W) × 36(D)mm
approx. 380g (batteries included)
Instruction manual, battery, Soft case, Label for Clip