Specification - KYORITSU 5406A Instruction Manual

Digital rcd tester
Table of Contents

Advertisement

 4. SPECIFICATION
● Measurement Specification
Function
× 1/2
× 1
× 5
230V+10%
DC TEST
AUTO RAMP
TEST
Instrument dimensions
Instrument weight
Reference conditions
Operating temperature
and humidity.
Storage temperature
and humidity.
Rated
Trip Current
voltage
Settings
(AC)
(I ⊿ n)
10/20/30
/200/300
/500mA
-15%
(10/20/30
50Hz
/200/300
/500mA)
+6mA dc
10/20/30
/200/300
/500mA
Trip Current
Duration
1000ms
1000ms
200ms
1000ms
Goes up by 10%
from 20% to 110%
of I ⊿ n.
300ms × 10
186×167×89mm
800g
Specifications are based on the following
conditions except where otherwise stated:
 1. Ambient temperature: 23 ± 5 ℃
 2. Relative humidity: 45% to 75%
 3. Position: horizontal
 4. AC power source: 230V, 50Hz
 5. Altitude: Up to 2000m
0 to +40℃, relative humidity 80% or less,
no condensation.
−20 to +60℃, relative humidity 75% or less,
no condensation.
̶ 9 ̶
Accuracy
Trip current
Trip Time
− 8% ∼− 2%
+2% ∼ +8%
0.6%
± 4dgt
− 10% ∼ +10%
− 8% ∼ +8%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents