Label Representation - Mendota SEABROOK D-40 Installation & Operating Instructions Manual

Direct vent gas fireplace
Table of Contents

Advertisement

CERTIFIED FOR CANADA
Also for use in mobile (manufactured) homes after first sale of home. Convenant également pour installations dans des
maisons mobiles.
Tested to (Testé aux normes) ANSI Z21.11.1-1993, CAN1-2.1-M89, CAN/CGA 2.17-M91, ANSI Z21.44-1995 and CGA
I.R. #41-M91.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal
injury, or loss of life. Refer to the owner's information manual provided with this appliance. Installation and service must be
performed by a qualified installer, service agency or the gas supplier. Use only glass assemblies certified for use with this
appliance. Do not operate with glass panel(s) removed, cracked, or broken.
MISE EN GARDE: Installation, réglage, modification, entretien ou depannage non appropriés pourront causer des blessures
ou des dommages materiels. Réferéz-vous au manuel du proprietaire fourni avac cet appariel. Pour assistance ou
renseignements complémentaires, veuillez consulter un installateur expérimenté, une agence dé depannage/entreitien ou cotre
compagnie gaziére. Pour utilisation avec les portes en verre certifiée l'appareil suelement. Ne pas opérer avec le verriére
enlever, craquelure, brise.
NOT FOR USE WITH SOLID FUEL (NE DOIT PASÉ UTILISÉ AVEC UN COMBUSIBLE SOLIDE)
f i r e - p a r t s . c o m
Input Rating (Btu/hr) 0-1370 m (Entrée nominale)
Min. Input Rating (Btu/hr) 0-1370 m (Mininale Entrée nominale)
Orifice (DMS) )-1370 m (Orifice)
Maximum output (Btu/hr) (Sortie maximale)
Manifold Pressure (in w.c./kPa) (Pression au collecteur)
Manifold Pressure, low (in w.c./kPa) Pression d'entree minimale)
Minimum Inlet Pressure (in w.c./kPa) (Pression d'entrée minimale)
This appliance must be installed in accordance with local codes if any; If not, follow ANSI Z223.1 or CAN/CGA-B149.
Mobile (Mfd.) home installations must adhere to Title 24 CFR, Part 3280, or CSA Z240.4.
Cet appareil sera installé conformémént avec les codes locaux, le cas écheant. Si aucun code n'existe, suivez la norme ANSI
Z223.1 ou la norme CAN/CGA (ACNOR)-B149.
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to sidewall
Unite en cote
CAUTION: Hot while in operation. Do not touch. Keep children, clothing, furniture, and flammable liquids or vapors
away. ATTENTION: L'appareil est chaud lorsqu'il fonctionne. Ne pas toucher l'appareil. Survieller les enfants. Garder les
vétements, les meubles, l'essence ou autres liquides a capeur inflammables loin de l'appareil.
Electrical Rating (Courant nominal): 120 volts 60 Hz Less than 2 Ampere
Manufactured by (Fabriqué par):

"LABEL REPRESENTATION"

LISTED GAS-FIRED DIRECT VENT ROOM HEATER
POÊLE AU GAZ HOMOLOGUE', A AÉRATION DIRECTE
HOMOLOGUÉ POUR LE CANADA
_________________________________________________
_________________________________________________
_______________________________________________
_______________________________________________
16 in.
Unit top to mantle
405 mm
Unité en manteau de cheminée
_______________________________________________
_______________________________________________
JOHNSON GAS APPLIANCE
DO NOT REMOVE OR COVER THIS LABEL
VEILLEZ Á NE JAMAIS ENLEVER NI DISSIMULER CETTE ÉTIQUETTE
WH# __________________
MODEL: _____
NATURAL GAS
(Gaz Naturel)
40,000
6,000
#48 & #32
29,500
3.5/0.87
1.7/0.42
5.0/1.25
CEDAR RAPIDS, IOWA
37
PROPANE GAS
(Gaz de petrole liquefie (GPL))
39,000
6,000
1/16" & #57
30,000
10.0/2.5
6.3/1.58
11.0/2.75
12 in.
305 mm

Advertisement

Table of Contents
loading