Mendota D30 Installation And Operating Instructions Manual

Mendota D30 Installation And Operating Instructions Manual

Direct vent gas fireplace insert heater

Advertisement

MODEL NO. D30 DIRECT VENT GAS FIREPLACE INSERT HEATER
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result causing property damage, personal injury or
loss of life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gasses, unless a
certified kit is used.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and must be installed.
Installation and Operating Instructions
85-03-01071-C
AVERTISSEMENT. Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incendie ou d'explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs
ou liquids inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incendies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
Cet appareil peut être installé dans une maison
préfabriquée (É.-U. seulement) ou mobile déjà installée à
demeure si les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types de
gaz indiqués sur la plaque signalétique. Une trousse de
conversion est fournie avec cet appareil.
Une barrière conçue pour réduire le risque de brûlures
du verre chaud est fournie avec cet appareil et doit être
installée.
D30 DEEP TIMBER

Advertisement

Table of Contents
loading

Summary of Contents for Mendota D30

  • Page 1 Installation and Operating Instructions MODEL NO. D30 DIRECT VENT GAS FIREPLACE INSERT HEATER WARNING: If the information in these instructions AVERTISSEMENT. Assurez-vous de bien suivre les is not followed exactly, a fire or explosion may instructions données dans cette notice pour réduire au...
  • Page 2 85-03-01071 D30 DEEP TIMBER Page I...
  • Page 3: Initial Firing And Curing Procedure

    The installer should perform these initial curing cycle procedures as the final step in the installation process before finishing materials are installed around this fireplace insert. See chapter 3.1.1 Mendota Fireplace insert Curing Instructions. Read and follow all instructions given in this Chapter and perform the 3-step curing cycle.
  • Page 4: Table Of Contents

    Table of Contents 1.1 I ....... 3 NITIAL IRING AND URING ROCEDURE 1.2 H ........3 URFACES ARE ORMAL 1.3 P .... 3 ERIODIC AND ANNUAL CLEANING ARE REQUIRED 3.3 E ......34 LECTRICAL ECHNICAL EFERENCES 2.1 SAFETY AND WARNING INFORMATION ....6 2.2 S .............
  • Page 5 6.1 R ....... 69 EQUIRED ERIODIC NSPECTIONS 6.2 C ......... 69 LEANING IEWING LASS 6.3 L ..E 4.7 A ZC W EVELING OLTS RROR OOKMARK NOT DEFINED TTACHING ARNING ABEL TO OODBURNING ........55 IREPLACE INSERT FLOOR 4.8 I ........
  • Page 6: Safety And Warning Information

    Building Permit & Inspection Requirements All installations of Mendota Fireplace inserts must comply with all the requirements stated in this Installation and Operating Manual. The dealer and/or installer must obtain all required building permits and inspection approvals from the local building inspection department or the local jurisdiction.
  • Page 7: Safety Warnings

    HIGH-ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7,500 ft., understand the need for gas input derating. Contact your local gas company to see if your gas type is already derated for your altitude or contact Mendota Technical Service for support.
  • Page 8 Never obstruct the flow of combustion and ventilation air. Keep the front of t he fireplace insert clear of all obstacles and materials for servicing and proper operation. Use only Mendota approved Screens, Fronts and Trim Kits.
  • Page 9 été plongée dans l’eau. Do not use any fronts or doors with this fireplace insert unless they are certified by Mendota and installed by a certified installer.
  • Page 10 A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation 85-03-01071 D30 DEEP TIMBER Page 10...
  • Page 11: General Technical References

    Never block off convection air openings or paths. Trim panels or surrounds shall not seal ventilation openings in the fireplace insert. Always use Mendota decorative fronts and Mendota approved vent systems and vent caps only. Keep the flue warm It is required to leave the pilot light running during winter months when outside daily high temperatures remain 50 F or lower.
  • Page 12 It is important that the blowers are turned on during this step to prevent the curing smoke from staining the wall finish above the fireplace insert . Mendota recommends completing Step 1 prior to install ation of wall finish materials.
  • Page 13: Mechanical Technical References

    The listing label is in the air gap beneath the firebox behind the lower grill of the Fireplace insert. It is secured to a chain and can be pulled out to be viewed. Figure 3-1 Listing Label 85-03-01071 D30 DEEP TIMBER Page 13...
  • Page 14 A few warnings or caution labels are attached to this appliance body as required per code to inform you of important facts. Make certain you heed all the warning and caution statements during installation and maintenance of this appliance. Figure 3-3 Figure 3-2 Figure 3-5 Figure 3-4 Figure 3-7 Figure 3-6 Figure 3-8 85-03-01071 D30 DEEP TIMBER Page 14...
  • Page 15 Figure 3-9 Figure 3-10 85-03-01071 D30 DEEP TIMBER Page 15...
  • Page 16 Install Only in Woodburning fireplace inserts This Mendota Insert must be installed and serviced by a qualified installer, service agency, or the gas supplier. This Gas Fired Insert Heater can only be installed inside a Masonry Woodburning Fireplace insert cavity or inside a Factory Built Zero Clearance Woodburning Fireplace insert Cavity.
  • Page 17 D30 DEEP TIMBER Fireplace insert Ratings Information This Mendota Insert must be installed in an existing Masonry Wood Burning Fireplace insert or a Factory Built ZC Wood Burning Fireplace insert. MINIMUM FIREPLACE INSERT CAVITY SIZE REQUIREMENT: 30-1/2” WIDE X 19” HIGH X 16-1/2” DEEP (depth can be reduced using a surround with a deep outer edge finish).
  • Page 18 NATURAL GAS INFORMATION: Factory equipped for Natural Gas. 4.5” WC Minimum inlet pressure required. LPG INFORMATION: LP conversion kit # HA-28-00194 is required. 12” WC Minimum inlet pressure required. For the D30 LPG application, the orifice is to be drill size #52. For higher altitude, adjustment to orifice size may be necessary.
  • Page 19 Note: For every 1” this fireplace insert is raised off the floor, the non-combustible hearth protection pad may be reduced by 2”. If this fireplace insert is raised more than 6” off the floor, no hearth protection pad is required. See Chapter 3.2.4.4 Hearth Pad Requirement Chapter 3.2.7.1 Hearth Pad Temperatures 85-03-01071 D30 DEEP TIMBER Page 19...
  • Page 20 Avoid installing carpets in the hearth pad area in front of this Fireplace insert unless this fireplace insert is raised at least 12 inches above the carpet level . Figure 3-14 HEARTH PROTECTON PAD 85-03-01071 D30 DEEP TIMBER Page 20...
  • Page 21 See for recommended 3.2.8.3 Suitable Finishing Materials R-Ratings, suitable facing materials. Note: The suggestions given in this section are Mendota Fireplace insert’s recommendations only. All local building code requirements must still be researched and followed. Figure 3-15 Re-facing Information 85-03-01071...
  • Page 22: Horizontal Clearance Reduction By 66

    NPFA 211 Approved: Install an R-1 rated ceramic board or R-1 rated mineral board on the wall you are attempting to protect. by using this method of protection, if the required horizontal clearance was 12”, the resulting clearance will be reduced by 50% to 6” between the heat source and the R-1 Rated wall board. 85-03-01071 D30 DEEP TIMBER Page 22...
  • Page 23 Suitable Mantel, Facing & Hearth Pad Materials Use of ceramic glazed tiles as facing materials around a Mendota Fireplace insert is approved. Use caution when selecting tile adhesives. Avoid premixed tile adhesives which contain products that can off gas for long periods when exposed to heat. Use Portland cement based unmixed tile adhesives or RTV Silicone to attach ceramic glazed tiles as facing in hot areas around this Fireplace insert.
  • Page 24 Mendota cautions that due to natural structural defects that can exist within marble and stone pieces, cracking and/or flaking of the marble or stone is possible and must be considered prior to selection and application around Mendota Fireplace inserts. Mendota further cautions that proper adhesives be used to attach stone facings. Pay attention to the potential of off-gassing of chemical vapors from mastic and other adhesives.
  • Page 25 R-Values of Common Facing Materials Material Thickness R-Value Cement Mortar 1/2" 0.100 Concrete 1" 0.095 Ceramic Tile 1/4" 0.020 Flagstone 1" 0.079 Granite 1" 0.083 Limestone 1" 0.153 Marble 1" 0.090 Sandstone 1" 0.079 Slate 1" 0.100 85-03-01071 D30 DEEP TIMBER Page 25...
  • Page 26: Paint Types Approved For Use

    Moisture content of the wood substrate is also of critical importance. High moisture content wood when heated will yield evaporation of the moisture and hydraulic pressure under the paint or sealants which can lead to peeling or bubbling. Always select the lowest moisture content wood substrate. 85-03-01071 D30 DEEP TIMBER Page 26...
  • Page 27 Many television manufacturers specify in their installation instructions that the television must not be installed near or above a heat source. The decision to install a television near or above a Mendota fireplace rests solely on the consumer. It is the consumers responsibility to satisfy television specifications and insure the television will not exceed maximum operation temperatures.
  • Page 28 24 inches above the top air gap of this fireplace. The cavity must be deep enough for the television to be recessed at least 2 inches in from the wall. 85-03-01071 D30 DEEP TIMBER Page 28...
  • Page 29: Figure

    Venting The D30 Insert must be vented vertically to the outside and must use one of the approved co -linear flexible ducting systems or a coaxial flexible ducting system. Mendota recommends that both exhaust and air intake flex liners be run all the way to the vent cap. Seals between flex liners and unit top and vent cap must be Do Not Use any silicone sealants at flex pipe joints.
  • Page 30: Figure

    Chimney flues can vary in shape, size and type. During inspection, make note of the type of the flue system used. Professionally clean and make any repairs before installing a Mendota gas Insert. Especially, pay attention to unlined flues which may have missing or severely damaged mortar joints.
  • Page 31: Figure

    For wider chimney caps and slabs, greater than 16” wide, increase the clearance above the vent cap to 6” minimum. If necessary, raise the slab to supply the required clearance. 85-03-01071 D30 DEEP TIMBER Page 31...
  • Page 32: Figure

    Alternatively, you may also vertically extend the wood burning flue liner up 24” higher than the top surface of the gas appliance vent cap. Figure 3-32 Side by Side Flues Figure 3-33 Side by Side Vent Caps 85-03-01071 D30 DEEP TIMBER Page 32...
  • Page 33 Decorative Cover for Vent Cap It is acceptable to install a decorative stone, metal or terra cotta cover to disguise the vent terminal/cap used on Mendota Inserts if the decorative cover meets the following minimum requirements: The decorative cover shall be manufactured from noncombustible materials.
  • Page 34: Electrical Technical References

    Plug the extension cord’s 3-prong plug into the newly installed junction box. Notice: Mendota wants to make you aware of current NEC Codes that may be enforced by local authorities. Mend ota cannot over-ride local building officials’ enforcement of National Electrical Codes.
  • Page 35 NFPA 70- National Electric Code or CSA C22.1- Canadian Electrical Code. Label all wires prior to disconnection when servicing control. Wiring Errors can cause improper and dangerous operation. Verify proper operation after servicing. 85-03-01071 D30 DEEP TIMBER Page 35...
  • Page 36 Blower System Wiring Diagram Figure 3-38 BLOWER SYSTEM WIRING DIAGRAM 85-03-01071 D30 DEEP TIMBER Page 36...
  • Page 37: Plumbing Technical References

    TRAIN. ADHERE STRICTLY TO LOCAL AND NATIONAL CODES. Gas Supply Line Sizing This Mendota Gas Fireplace Insert comes equipped with a 1/2" N.P.T. Female inlet. Gas supply piping can enter the Fireplace Insert cabinet on the left or right side.
  • Page 38 Local requirements supersede all other codes. Figure 3-42 Keyed Manual Gas Shutoff Valve 85-03-01071 D30 DEEP TIMBER Page 38...
  • Page 39 Based on the gas line size you have selected use an appropriate NPT fitting to adapt and connect to the 1/2” female NPT end. Figure 3-43 BALL VALVE INLET 85-03-01071 D30 DEEP TIMBER Page 39...
  • Page 40 This appliance has been converted for use at an altitude of: Orifice size: Manifold Pressure: Input (Btu/h): Fuel Type: Date of conversion: Converted by: Cet appreeil a été converti au ____ Injecteur ________ Pression à la tubulure d'alimentation _____________ Déoit calorifique ______________ 85-03-01071 D30 DEEP TIMBER Page 40...
  • Page 41: Installation Checklist

    ❑ Install log set, coals and inswool media. ❑ Test fire Insert. See ❑ Teach consumer all functions of this insert ❑ Complete warranty registration at http://mendotahearth.com/gas-fireplace insert-and-stove-registration.php This installation was performed and completed by: Date: 85-03-01071 D30 DEEP TIMBER Page 41...
  • Page 42: Preparing For Installation

    Lift the outer box vertically straight upward until lower edge of the box clears the top of the unit body. Set the box aside. Mendota recommends recycling the outer box. Figure 4-1 Outer Box Removal...
  • Page 43 Contents of the Manual Packet Once the outer box is removed, you will find the Fireplace insert body and a manual packet. This manual packet includes the items shown in the table, below. Contact Mendota Technical Service if any parts are missing. Owner’s Manual.
  • Page 44: Leveling Bolts

    The leveling bolts supplied are designed specifically for application with this product. only use leveling bolts supplied by Mendota and for leveling purposes only. Never use leveling bolts for purposes of lifting unit up to make up for ash lip heights or other lifting or raising needs.
  • Page 45: How To Remove Door

    Figure 4-5 Door Operation Fireplace insert) until it clears doorframe. Raise Bar until it fits securely in Bar Holding Brackets on doorframe. Repeat procedure for opposite Holding Bar. Door is now connected and sealed to unit. 85-03-01071 D30 DEEP TIMBER Page 45...
  • Page 46: Natural Gas To Lpg Conversion

    Figure 4-7 Pilot Orifice Access CAUTION: Always use one 7/16” open end wrench and one large pliers or vice grips tool to hold, loosen and tighten pilot hood base to prevent damage to pilot mount bracket. 85-03-01071 D30 DEEP TIMBER Page 46...
  • Page 47 The pilot light flames must be a minimum of 1” long and must overlap the propagation ports on both the rear and front burner legs. Verify that the burner tubes ignit e quickly and the burner flames propagate smoothly along the entire length of the burner. 85-03-01071 D30 DEEP TIMBER Page 47...
  • Page 48: Venting

    4” exhaust flex and 6” air intake flex with spring spacers between the two flex pipes. NOTE: Mendota recommends that both exhaust and air intake flex liners be run all the way to the vent cap. Seals between flex liners and unit top and vent cap must be permanent and as air tight as possible. Never use silicone sealants in pipe joints.
  • Page 49 12" (300 mm) above the fireplace insert hearth. The person below should wear leather gloves and Safety Glasses during this process to avoid being cut and to safeguard eyes from flying debris. 85-03-01071 D30 DEEP TIMBER Page 49...
  • Page 50 WARNING: FAILURE TO INSTALL THE SOCK GASKET PROPERLY WILL RESULT IN SOOTING, GHOSTING AND UNACCEPTABLE FLAME APPEARANCE DUE TO EXHAUST GASES RECIRCULATING BACK INTO THE FIREBOX THROUGH THE COMBUSTION AIR INTAKE PATHS. Figure 4-12 VENT ADAPTER ASSEMBLY Figure 4-11 SOCK GASKET INSTALLATION 85-03-01071 D30 DEEP TIMBER Page 50...
  • Page 51 Reinstall the baffle in its original position and secure in place using the two hex head screws you removed earlier. Figure 4-13 VENT ADAPTER INSTALLATION 85-03-01071 D30 DEEP TIMBER Page 51...
  • Page 52 Natural Vent System (B-Vent System) using a single 4” Exhaust Liner. Select one Vent System based on the particular application and chimney size. Figure 4-15 COAXIAL VENT Figure 4-14 COLINEAR VENT Figure 4-16 NATURAL VENT (B-VENT) 85-03-01071 D30 DEEP TIMBER Page 52...
  • Page 53 Attaching Flue Liners to Vent Cap Four hose clamps are supplied with each Mendota vent kit. Four #8 sheet metal screws are needed which are not supplied with Mendota vent kits. For vent kits (other brands) obtained from other distributors or suppliers, acquire four 4”...
  • Page 54 Figure 4-18 Vent Adapter Flex Connection clamp from sliding off. Hose Clamp first. Secure w/ Screw above Hose 4. Repeat procedure for 4” air intake flex liner. Clamp 85-03-01071 D30 DEEP TIMBER Page 54...
  • Page 55: Attaching Warning Label To Fireplace Insert Floor

    Before installing this appliance in the ZC Woodburning Fireplace insert, this label must be mechanically attached to the ZC Woodburning Fireplace insert floor using self-drilling sheet metal screws (not supplied). Secure this label on floor on the floor adjacent to the right or left walls. Figure 4-19 Warning Label 85-03-01071 D30 DEEP TIMBER Page 55...
  • Page 56: Insert Body Installation

    5. Push Insert Body all the way into fireplace insert cavity until Surround or Faceplate touches the facing material. 4.9 SURROUND/FACEPLATE INSTALLATION NOTE: Faceplate surrounds are only used for Mendota Door Kits (Andover, Bentley and Prairie). 3-piece surrounds are used for all other decorative fronts and safety screen only installations.
  • Page 57: Log Set Installationi

    Place Log B between rear burner tube and front burner tube, to the right side of pilot light assembly. Slide Log #B to the right until log #B’s right tip touches curve in burner tube. as shown below. 85-03-01071 D30 DEEP TIMBER Page 57...
  • Page 58 Place log “C” behind on top of Log #A and Log #B, as shown. Wide end of Log #C sits on top of Log #A and the pin protruding up from top of Log #B slides into a hole in the base of Log #C. 85-03-01071 D30 DEEP TIMBER Page 58...
  • Page 59 Log “D” has a pin in its base. This pin slides into a hole on the rear shelf, right side. The pin protruding upward from Log #C slides into a hole in the base of Log #D. 85-03-01071 D30 DEEP TIMBER Page 59...
  • Page 60 Place log “E” as shown below, to the left side of the pilot light assembly. Look at the diagram at the bottom of this page to determine the exact position of this log. This log should use the center Log Iron bar for support. 85-03-01071 D30 DEEP TIMBER Page 60...
  • Page 61 "lifting" off burner. ❑ Reinstall glass. ❑ You can now proceed with normal daily operation. In daily operation main burner should always be lit with Insert glass in place. 85-03-01071 D30 DEEP TIMBER Page 61...
  • Page 62: Lighting Checklist

    IMPORTANT: Try each new shutter setting approx. ½ hr. before mak ing additional changes. NOTE: Changes in front burner flame can be made by re -arranging the coals and front burner air shutter opening. 85-03-01071 D30 DEEP TIMBER Page 62...
  • Page 63: Aesthetic Considerations

    We have designed this manual to help you enjoy all that your Mendota Fireplace insert has to offer. You will find tips, operating instructions, and frequently asked questions to support the features and functions of your Fireplace insert.
  • Page 64: First Time Lighting Instructions

    Logs or coals must not block pilot flame or main burner flame. Vent system must be leak proof. DO NOT PROCEED WITH OPERATION UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! 85-03-01071 D30 DEEP TIMBER Page 64...
  • Page 65: T Oturn Off Gas Tof

    Turn “OFF" the wall thermostat or timer control device. Pilot will remain lit for return to normal service. 2. For complete shutdown turn Gas Cock Dial to "OFF". Turn off the internal manual shutoff valve in the appliance. See 3.6.6 Factory Installed Manual Gas Shutoff Valve. 85-03-01071 D30 DEEP TIMBER Page 65...
  • Page 66: Frequently Asked Questions

    Where can I find the model and serial numbers? When requesting service, you will be asked to provide the model number and serial number to your Mendota dealer. This information will expedite the warranty verification process. The Listing Label contains the model number and serial number for your particular appliance.
  • Page 67 3” to 12” long area) and the gasket adhesive in no longer functional to stick to glass, then replace the gasket. Visually inspect the vent terminal (vent cap) for leaves, twigs and other debris accumulation. Clean if required. 10. Clean door glass. 85-03-01071 D30 DEEP TIMBER Page 67...
  • Page 68 These adjustments should be made by a qualified technician to achieve the best flame performance. Contact your installer or Mendota dealer if you feel your fireplace insert is not burning correctly. Improper setup and adjustment is not covered under warranty.
  • Page 69: Required Periodic Inspections

    The leveling bolts supplied are designed specifically for application with this product. only use leveling bolts supplied by Mendota and for leveling purposes only. Never use leveling bolts for purposes of lifting unit up to make up for ash lip heights or other lifting or raising needs.
  • Page 70 Perform this step after you have measured the firebox floor for level surface characteristics. Tip the Insert body on its back on the wooden pallet. Thread one leveling bolt in to each leveling bolt receiving fastener. Thread the bolt in as far as necessary to achieve the leveling effect desired. Figure 4-4 Leveling Bolts Installation 85-03-01071 D30 DEEP TIMBER Page 70...
  • Page 71: How To Remove Door Required

    Check joints between the gasket pieces at the corners. They should butt against each other to create a seal. Gaps between gasket pieces can cause exhaust leaks and lead to acrid smell concerns. 85-03-01071 D30 DEEP TIMBER Page 71...
  • Page 72: Over Firing Or Under Firing Of

    If you are using a “backyard” Natural Gas well as the gas source, you must submit formal gas analysis data sheets to Mendota Fireplace insert s for review and calculation of proper main burner orifice sizes prior to first firing. It is known that unpurified Natural Gas from “backyard” wells can contain high energy levels causing over firing.
  • Page 73: Replacement Parts Information

    PART NO DESCRIPTION HA-27-00073 DOOR GASKET 05-04-00035 PILOT ASSEMBLY. NAT. GAS 65-06-00449 GLASS, D30 HA-28-00194 LP KIT DOOR FRAME ASSEMBLY, D30 65-14-00052 ORIFICE (LPG) #52 HA-28-00040 35-01-00240 COALS 12 OZ BAG 10-10-00104 ON/OFF SWITCH GLOWING INSWOOL 65-14-00035 ORIFICE (NAT. GAS) 35”...
  • Page 74 Convection Air Blower System Parts Item 1 15-02-00120 BLOWER, RH Item 2 15-02-00121 BLOWER, LH Figure 6-3 D30 DEEP TIMBER BLOWER ASSEMBLIES Valve Assembly Replacement Parts Item 1 65-14-00035 NG Orifice, #35 Item 2 65-14-00052 LPG Orifice, #52” Item 2...
  • Page 75 Glass Frame Parts Replacement Procedure WARNING: do not use substitute materials. All replacement materials must be certified and obtained through Mendota fireplace insert s. TO REPLACE DAMAGED GLASS DRILL RIVETS USING 1/8" DRILL BIT. REMOVE 3 RIVETS EACH SIDE & BRACKETS.
  • Page 76: Checklist

    ❑ Burner flames are “stable” and are not “lifting” off burner. ❑ Inform owner that an initial curing step is required. Read and follow Mendota Fireplace and Insert Curing Instructions (found on unit and in owner’s manual). Smoke will emit during initial curing step.
  • Page 77: Warranty Policy Statement

    7.2 WARRANTY POLICY STATEMENT Mendota Fireplace, a division of Johnson Gas Appliance Company, extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
  • Page 78: Conditions

    Owner accepts that this appliance requires close monitoring of children and vulnerable individuals who are in the vicinity of this appliance when it is in operation. Mendota does not assume or accept any liability claims for burns or other physical or material damages resulting from touching hot glass surface and hot metal surfaces that are part of this appliance or other adjacent object such as hearth pads and mantels that may heat up during operation of this appliance.
  • Page 79 The original purchaser’s exclusive remedy under this warranty, and Mendota’s sole obligation under this warranty, express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. In no event will Mendota be liable under this warranty for any incidental or consequential commercial damages or damages to property.
  • Page 80 Owner Registration After installation, Mendota fireplace owners must register with Mendota to qualify for the Lifetime Limited Warranty within 30 days. Product registration will activate your Lifetime Limited Warranty. Owners should complete the forms available at: mendotahearth.com/warranty Note: Your Mendota dealer can assist with warranty applications and information.
  • Page 82 Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids, Iowa 52405 Mendota Warranty Registration...

This manual is also suitable for:

D40 deep timber

Table of Contents