14.
TYPICALLY
Use Mendota Co-Axial Vent Kit -- # AA-11-00378 4" exhaust flex pipe extends full length of chimney from
vent boot adapter to vent cap. 6" inlet flex pipe extends from vent boot adapter to existing chimney, above
damper area (approx. 4 - 5 ft.). Tightly secure flex vents with clamps provided. Seal vent cap/flashing to top
of chimney with weatherproof sealer.
Seal areas between 6" flex pipe and chimney, at damper area, with unfaced fiberglass insulation.
FOR MASONRY FIREPLACES
15. TYPICALLY
Use Mendota Co-Linear Vent Kit -- # AA-11-00377 4" exhaust flex pipe extends full length of chimney - from
vent boot adapter to vent cap. 4" inlet flex pipe extends from vent boot adapter to existing chimney, above
damper area (aprox.4-5 ft.). Tightly secure 4" flex pipes using clamps provided. Seal vent cap/flashing to top
of chimney with weatherproof sealer. Seal areas between 4" flex pipes and existing chimney, at damper area,
with unfaced fiberglass insulation.
16.
You are now ready to install the Mendota Gas Insert.
A. Lift Insert vertically from carton/pallet.
f i r e - p a r t s . c o m
17.
Remove 5/16" nut and locking u-clamp from vent boot adapter (See FIG. 7A, Pg. 12
18.
You are now ready to hook up the Insert to gas supply. Be sure gas plumbing instructions, [Pg. 15 & 16],
and all state and local codes have been carefully followed. Be sure all items on Installation Check-Off List
[Pg. 17] have been completed.
NOTE: AGA APPROVED FLEX LINES ARE APPROVED FOR USE WITH MENDOTA INSERTS.
FOR FACTORY BUILT ZC FIREPLACES
FIGURE 6 : OPENING THE GLASS DOOR
, REFER TO PAGE 7.
, REFER TO PAGE 7.