Table Of Contents; Specifications - Mendota SEABROOK D-40 Installation & Operating Instructions Manual

Direct vent gas fireplace
Table of Contents

Advertisement

SPECIFICATIONS..................................................................................................................................................................1
CONGRATULATIONS! .........................................................................................................................................................2
GENERAL INFORMATION .................................................................................................................................................3
ELECTRICAL REQUIREMENTS........................................................................................................................................3
SPECIFICATIONS & CLEARANCES .................................................................................................................................4
INSTALLATION INSTRUCTIONS......................................................................................................................................6
FLUE VENTING .....................................................................................................................................................................7
RAISED HEARTH SPECIFICATIONS..............................................................................................................................14
GAS SUPPLY REQUIREMENTS .......................................................................................................................................15
GAS PRESSURE REQUIREMENTS ..................................................................................................................................16
INSTALLATION CHECK OFF LIST.................................................................................................................................16
LIGHTING CHECK OFF LIST...........................................................................................................................................17
LIGHTING INSTRUCTIONS..............................................................................................................................................18
DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS.....................................................................................20
WALL SWITCH, REMOTE CONTROL OR THERMOSTAT OPERATION..............................................................28
BLOWER OPERATION AND WIRING ............................................................................................................................29
BLOWER (S) REMOVAL ....................................................................................................................................................30
CUSTOMER INFORMATION AND TROUBLE-SHOOTING .......................................................................................31
TROUBLE SHOOTING MENDOTA GAS FIREPLACE INSERT.................................................................................32
GAS FLAME ADJUSTMENT..............................................................................................................................................32
MAINTENANCE ...................................................................................................................................................................33
REPLACEMENT PARTS LIST...........................................................................................................................................34
f i r e - p a r t s . c o m
NATURAL TO LP GAS CONVERSION ............................................................................................................................35
"LABEL REPRESENTATION" ..........................................................................................................................................37
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM ....................................................38
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY ................................................42
BTUH ....................................................NAT. GAS
BTUH ....................................................L.P. GAS
NOTE: LP CONVERSION KITS ARE INCLUDED WITH EACH D-40 DEEP TIMBER INSERT - SEE Pg 35
MAIN ORIFICE......REAR BURNER: 32" NAT. GAS [1/16" L.P. GAS] - FRONT BURNER: #48 NAT. [#57 LP]
OVERALL EFFICIENCY ......................EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.)
FLUE VENT LINER ..............................CO-LINEAR - 4" DIAMETER EXHAUST & 4" DIAMETER INLET or
NET WEIGHT ........................................195 lbs.
SAFETY..................................................AGA CERTIFIED PILOT GENERATOR, MILLIVOLT SYSTEM
GAS REQUIREMENTS .........................SUPPLY PRESSURE:
ELECTRICAL REQUIREMENTS ......
LISTINGS INTERTEK TESTING SERVICES TESTED TO: ANSI Z21.11.1-1993 & CAN1-2.1 M89 "GAS-FIRED VENTED
ROOM HEATERS" & CAN/CGA 2.17-M91 "GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES", ANSI Z21.44-1995
"GAS-DIRECT VENT WALL FURNACES" AND CGA INTERIM REQUIREMENT #41-M91 "DIRECT VENT GAS
FIREPLACES" AND UL307B "MOBILE HOME, APPROVED EXCEPT RECREATIONAL VEHICLES"
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American National
Standards Institute - ANSI Gas Appliance Safety Standards. For more information see Pg. 37. The Mendota Gas Fireplace
Insert has been tested and certified by Intertek Testing Services. 8431 Murphy Drive, Middleton, WI 53562.
INSERT INCLUDES HEARTHGLO COMBUSTION SYSTEM, DUAL HOT AIR BLOWERS, 6-PIECE CERAMIC FIBER LOG SET & COALS, NEO-
CERAM GLASS, PIEZO IGNITER AND AGA CERTIFIED SAFETY SYSTEM.
OPTIONS: BLACK OR BRASS GRILL SETS, BLACK OR GOLD FILIGREE FRONTS, BLACK ARCHED DOOR KITS (ANDOVER), 3 SIZES OF
SURROUNDS & 2 TYPES (CO-LINEAR OR COAXIAL) OF VENTING KITS.

TABLE OF CONTENTS

SPECIFICATIONS

MODEL D-40 DEEP TIMBER
High Fire -
40,000
39,000
CO-AXIAL - 4" DIAMETER EXHAUST & 6 " DIAMETER INLET
ACTIVATED WITH SWITCH, REMOTE CONTROL OR THERMOSTAT.
NAT. GAS:
7" W.C.
L.P. GAS:
11" W.C.
120 Volts AC, 2 Amps
1
Adj. to - Low Fire
-----
6,500
-----
6,500
GAS INLET: 3/8" N.P.T.
[5.0" W.C. MIN., 11" W.C. MAX.]
[11" W.C. MIN., 13" W.C. MAX.]