Thunderbolt™ 2 Interface Card & LEDs
There are 10 LEDs on the Thunderbolt™ 2 Interface card. These LEDs are very essential in checking the
power status of the board. It also serves as failure indicators and helps in troubleshooting hardware
problems.

Fully Operational: With monitor attached -LEDS

When the Thunderbolt™ 2 Interface card is fully operational and with an external Display device
attached, 7 solid Green LEDs (D1,D3,D4,D5,D6,D7 and D9) are illuminated. See picture on FIGURE T2-A.
If you do not have an external display attached, only 5 Green LEDs are illuminated. See FIGURE T2-B.
FIGURE T2-A
If the above LEDs are not coming ON, it is an indication that your board is not getting power or the board is
faulty or defective. Please check the following:
1.
Standby-power cable (
power connector (J7).
2.
Thunderbolt™ 2 Interface card is seated all the way in the PCIe slot. Try reseating the card in the
PCIE slot.

Fully Operational: No monitor attached -LEDS

If there is no Display Monitor attached to Thunderbolt™ 2 Interface card it would only show 5 illuminated
solid GREEN LEDs (D3, D4,D6,D7 and D9), this is normal. See FIGURE T2-B below.
see Chapter 4
) is firmly connected to Thunderbolt™ 2 Interface card