LED INDICATION

-HX-40/40AM
DETECTOR CONDITION
Warm-up
Alarm
Anti-Masking
booting
(Anti-Masking
start up)
Trouble
output
Masking detection
-HX-40DAM
DETECTOR CONDITION
Warm-up
Alarm
PIR detection
MW detection
Anti-Masking
booting
(Anti-Masking
start up)
Trouble
output
Masking detection
HX-40DAM_EN.indd 17
HX-40DAM_EN.indd 17
Red
Yellow
(HX-40DAM only)
Green
(HX-40DAM only)
LED INDICATOR (RED ONLY)
Blinks for approx. 60 sec.
Blinks 2 times and goes off for 5 sec. and then repeats for 180 sec.
Blinks 3 times and goes off for 3 sec. and then repeats.
Blinks for approx. 60 sec.
Green and Red blink 2 times simultaneously and go off for
5 sec. This sequence is repeated for 180 sec.
Green and Red blink 3 times simultaneously and go off for
3 sec. This sequence is repeated.