When using the bracket
1
In
2
Tilt the bracket about 45° and
pass through the wire.
In
Magnet
switch
Install the bracket and the main unit to
4
the wall surface.
3
WALK TEST
Set the DIP switch 1 (LED ON/OFF) to
1
"ON".
Note>>
The switch is set "ON" by factory
default.
If the LED indication is not required at all
3
times, set the DIP switch 1 (LED ON/
OFF) to "OFF".
HX-40DAM_EN.indd 12
HX-40DAM_EN.indd 12
Fix
In
4
6
3
Wiring
Out
sponge pad
5
2
- 12 -
Connect the universal magnet switch wiring
to the tamper terminal of the main unit.
Check that the detector detects an
object in the intended detection area.
The installation has been successful if
the LED lights for two seconds after a
person walks into the detection area.
Detected
Not detected
Note>>
For the walk test, move more than 1.0 m
(3'3") away from the detector.
5
Out