B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 54 of 61)
ADDR
REGISTER NAME
CAD1
Direct Input/Output Channel 1 CRC Alarm
Message Count
CAD2
Direct Input/Output Channel 1 CRC Alarm
Threshold
CAD3
Direct Input/Output Channel 1 CRC Alarm Events
B
CAD4
Reserved (4 items)
CAD8
Direct Input/Output Channel 2 CRC Alarm Function 0 to 1
CAD9
Direct Input/Output Channel 2 CRC Alarm
Message Count
CADA
Direct Input/Output Channel 2 CRC Alarm
Threshold
CADB
Direct Input/Output Channel 2 CRC Alarm Events
CADC
Reserved (4 items)
CAE0
Direct Input/Output Ch 1 Unreturned Messages
Alarm Function
CAE1
Direct Input/Output Ch 1 Unreturned Messages
Alarm Msg Count
CAE2
Direct Input/Output Ch 1 Unreturned Messages
Alarm Threshold
CAE3
Direct Input/Output Ch 1 Unreturned Messages
Alarm Events
CAE4
Reserved (4 items)
CAE8
Direct Input/Output Ch 2 Unreturned Messages
Alarm Function
CAE9
Direct Input/Output Ch 2 Unreturned Messages
Alarm Msg Count
CAEA
Direct Input/Output Ch 2 Unreturned Messages
Alarm Threshold
CAEB
Direct Input/Output Channel 2 Unreturned
Messages Alarm Events
CAEC
Reserved (4 items)
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID
(GOID)
CB21
Remote Device 1 GOOSE Ethernet APPID
CB22
Remote Device 1 GOOSE Dataset
CB23
Remote Device 1 in PMU Scheme
CB24
Reserved
CB25
...Repeated for Device 2
CB4A
...Repeated for Device 3
CB6F
...Repeated for Device 4
CB94
...Repeated for Device 5
CBB9
...Repeated for Device 6
CBDE
...Repeated for Device 7
CC03
...Repeated for Device 8
CC28
...Repeated for Device 9
CC4D
...Repeated for Device 10
CC72
...Repeated for Device 11
CC97
...Repeated for Device 12
CCBC
...Repeated for Device 13
CCE1
...Repeated for Device 14
CD06
...Repeated for Device 15
CD2B
...Repeated for Device 16
B-62
RANGE
100 to 10000
1 to 1000
0 to 1
1 to 1000
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
---
0 to 16383
0 to 16
0 to 1
0 to 3
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
---
F209
---
1
F001
---
1
F184
---
1
F126
---
1
F626
DEFAULT
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
"Remote
Device 1"
0
0 (Fixed)
0 (No)
0 (None)
GE Multilin