GE B30 UR Series Instruction Manual page 432

Bus differential system
Hide thumbs Also See for B30 UR Series:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 6 of 61)
ADDR
REGISTER NAME
1A1A
Source 1 Phase BC or BA Voltage Angle
1A1B
Source 1 Phase CA or CB Voltage Magnitude
1A1D
Source 1 Phase CA or CB Voltage Angle
1A1E
Source 1 Auxiliary Voltage RMS
B
1A20
Source 1 Auxiliary Voltage Magnitude
1A22
Source 1 Auxiliary Voltage Angle
1A23
Source 1 Zero Sequence Voltage Magnitude
1A25
Source 1 Zero Sequence Voltage Angle
1A26
Source 1 Positive Sequence Voltage Magnitude
1A28
Source 1 Positive Sequence Voltage Angle
1A29
Source 1 Negative Sequence Voltage Magnitude
1A2B
Source 1 Negative Sequence Voltage Angle
1A2C
Reserved (20 items)
1A40
...Repeated for Source 2
1A80
...Repeated for Source 3
1AC0
...Repeated for Source 4
1B00
...Repeated for Source 5
1B40
...Repeated for Source 6
Source Frequency (Read Only) (6 modules)
1D80
Frequency for Source 1
1D82
Frequency for Source 2
1D84
Frequency for Source 3
1D86
Frequency for Source 4
1D88
Frequency for Source 5
1D8A
Frequency for Source 6
Breaker Flashover (Read/Write Setting) (2 modules)
2196
Breaker Flashover 1 Function
2197
Breaker Flashover 1 Side 1 Source
2198
Breaker Flashover 1 Side 2 Source
2199
Breaker Flashover 1 Status Closed A
219B
Breaker Flashover 1 Status Closed B
219D
Breaker Flashover 1 Status Closed C
219F
Breaker Flashover 1 Voltage Pickup Level
21A0
Breaker Flashover 1 Voltage Difference Pickup
Level
21A2
Breaker Flashover 1 Current Pickup Level
21A3
Breaker Flashover 1 Pickup Delay
21A4
Breaker Flashover 1 Supervision Phase A
21A6
Breaker Flashover 1 Supervision Phase B
21A8
Breaker Flashover 1 Supervision Phase C
21AA
Breaker Flashover 1 Block
21AC
Breaker Flashover 1 Events
21AD
Breaker Flashover 1 Target
21AE
Reserved (4 items)
21B2
...Repeated for Breaker Flashover 2
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Field Unit Raw Data Settings (Read/Write Setting)
2460
Field Raw Data Port
2461
Field Raw Data Freeze
B-14
RANGE
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
---
2 to 90
2 to 90
2 to 90
2 to 90
2 to 90
2 to 90
0 to 1
0 to 5
0 to 6
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1.5
0 to 100000
0 to 1.5
0 to 65.535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 2
---
0 to 1
0 to 7
0 to 1
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
---
---
F001
Hz
0.001
F003
Hz
0.001
F003
Hz
0.001
F003
Hz
0.001
F003
Hz
0.001
F003
Hz
0.001
F003
---
1
F102
---
1
F167
---
1
F211
---
1
F300
---
1
F300
---
1
F300
pu
0.001
F001
V
1
F060
pu
0.001
F001
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F109
---
---
F001
---
1
F126
---
1
F244
---
1
F102
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
0 (SRC 1)
0 (None)
0
0
0
850
1000
600
100
0
0
0
0
0 (Disabled)
0 (Self-Reset)
0
0 (No)
6 (H1a)
0 (Disabled)
GE Multilin