B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 58 of 61)
ADDR
REGISTER NAME
D347
IEC 61850 GGIO2.CF.SPCSO40.ctlModel Value
D348
IEC 61850 GGIO2.CF.SPCSO41.ctlModel Value
D349
IEC 61850 GGIO2.CF.SPCSO42.ctlModel Value
D34A
IEC 61850 GGIO2.CF.SPCSO43.ctlModel Value
B
D34B
IEC 61850 GGIO2.CF.SPCSO44.ctlModel Value
D34C
IEC 61850 GGIO2.CF.SPCSO45.ctlModel Value
D34D
IEC 61850 GGIO2.CF.SPCSO46.ctlModel Value
D34E
IEC 61850 GGIO2.CF.SPCSO47.ctlModel Value
D34F
IEC 61850 GGIO2.CF.SPCSO48.ctlModel Value
D350
IEC 61850 GGIO2.CF.SPCSO49.ctlModel Value
D351
IEC 61850 GGIO2.CF.SPCSO50.ctlModel Value
D352
IEC 61850 GGIO2.CF.SPCSO51.ctlModel Value
D353
IEC 61850 GGIO2.CF.SPCSO52.ctlModel Value
D354
IEC 61850 GGIO2.CF.SPCSO53.ctlModel Value
D355
IEC 61850 GGIO2.CF.SPCSO54.ctlModel Value
D356
IEC 61850 GGIO2.CF.SPCSO55.ctlModel Value
D357
IEC 61850 GGIO2.CF.SPCSO56.ctlModel Value
D358
IEC 61850 GGIO2.CF.SPCSO57.ctlModel Value
D359
IEC 61850 GGIO2.CF.SPCSO58.ctlModel Value
D35A
IEC 61850 GGIO2.CF.SPCSO59.ctlModel Value
D35B
IEC 61850 GGIO2.CF.SPCSO60.ctlModel Value
D35C
IEC 61850 GGIO2.CF.SPCSO61.ctlModel Value
D35D
IEC 61850 GGIO2.CF.SPCSO62.ctlModel Value
D35E
IEC 61850 GGIO2.CF.SPCSO63.ctlModel Value
D35F
IEC 61850 GGIO2.CF.SPCSO64.ctlModel Value
Remote Device Status (Read Only) (16 modules)
D380
Remote Device 1 StNum
D382
Remote Device 1 SqNum
D384
...Repeated for Remote Device 2
D388
...Repeated for Remote Device 3
D38C
...Repeated for Remote Device 4
D390
...Repeated for Remote Device 5
D394
...Repeated for Remote Device 6
D398
...Repeated for Remote Device 7
D39C
...Repeated for Remote Device 8
D3A0
...Repeated for Remote Device 9
D3A4
...Repeated for Remote Device 10
D3A8
...Repeated for Remote Device 11
D3AC
...Repeated for Remote Device 12
D3B0
...Repeated for Remote Device 13
D3B4
...Repeated for Remote Device 14
D3B8
...Repeated for Remote Device 15
D3BC
...Repeated for Remote Device 16
Contact Outputs (Read/Write Setting) (64 modules)
DC90
Contact Output 1 Name
DC96
Contact Output 1 Operation
DC98
Contact Output 1 Seal In
DC9A
Latching Output 1 Reset
DC9C
Contact Output 1 Events
B-66
RANGE
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 4294967295
0 to 4294967295
---
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F003
---
1
F003
---
---
F205
---
1
F300
---
1
F300
---
1
F300
---
1
F102
DEFAULT
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
"Cont Op 1"
0
0
0
1 (Enabled)
GE Multilin

Advertisement

Table of Contents
loading

This manual is also suitable for:

B30

Table of Contents