Sensor (duplex/MPF input) service check
Action
Step 1
Check the error that appeared.
Is the error 100.35?
Step 2
a
Remove the cable cover from the front door.
b
Check if the cable is properly connected to the door and to the
JMSNS1 connector on the controller board.
Is the cable properly connected at both ends?
Step 3
Reconnect the cable.
Does the problem remain?
Step 4
Replace the cable.
Does the problem remain?
Step 5
Check the following sensors for proper connection, and reseat if
necessary:
•
Sensor (MPF empty)
•
Sensor (duplex path 1)
•
Sensor (fuser buckle)
•
Sensor (narrow media)
Does the problem remain?
Step 6
Check the sensors for damage, and replace if necessary.
Does the problem remain?
Diagnostic information
195
Yes
No
Go to step 2.
Go to step 5.
Go to step 4.
Go to step 3.
Go to step 4.
The problem is
solved.
Contact the next
The problem is
level of support.
solved.
Go to step 6.
The problem is
solved.
Contact the next
The problem is
level of support.
solved.
7528