Default configuration settings are applied to the server at one of the following times:
Upon the first system power-up
After defaults have been restored
Default configuration settings are sufficient for typical server operations; however, you can modify
configuration settings as needed. The system prompts you for access to the System Utilities each time
the system is powered up.

Embedded Diagnostics option

The system BIOS in all ProLiant Gen9 servers includes an Embedded Diagnostics option in the ROM.
The Embedded Diagnostics option can run comprehensive diagnostics of the server hardware,
including processors, memory, drives, and other server components.
For more information on the Embedded Diagnostics option, see the UEFI System Utilities User Guide
for ProLiant Gen9 Servers on the Hewlett Packard Enterprise website
(http://www.hpe.com/info/ProLiantUEFI/docs).

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the graphics server blade serial number and the
product ID.
During the graphics server blade startup sequence, press the F9 key to access UEFI System
1.
Utilities.
Select the System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options
2.
> Advanced System ROM Options > Serial Number, and then press the Enter key.
Enter the serial number and press the Enter key. The following message appears:
3.
The serial number should only be modified by qualified service
personnel. This value should always match the serial number located on
the chassis.
Press the Enter key to clear the warning.
4.
Enter the serial number and press the Enter key.
5.
Select Product ID. The following warning appears:
6.
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
Enter the product ID and press the Enter key.
7.
Press the F10 key to confirm exiting System Utilities. The graphics server blade automatically
8.
reboots.

HPE Insight Diagnostics

The Insight Diagnostics is a proactive graphics server blade management tool, available in both offline
and online versions, that provides diagnostics and troubleshooting capabilities to assist IT
Key
Enter
F10
F1